CONNECTATUBE SP-2JB M25 Tubular Junction Box
CONNECTATUBE SP-2JB M25 Tubular Junction Box is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Complete the Installation
Products commonly used with this item.
Description
Description
SOLCO SP-2JB Connectatube M25 Tubular Junction Box
The SOLCO SP-2JB Connectatube is a professional-quality M25 tubular junction box designed for power and heating cable connections in SOLCO Pyroelec trace heating systems.
Featuring a slim 32mm outer diameter and two cable entries, the Connectatube provides a compact connection point for a power supply to one heating cable circuit, or for splicing one heating cable circuit to another.
Manufactured from PA66 / TPE, the tough weatherproof enclosure is IP68 rated and contains an internal 3-pole terminal system, rated at 32A / 450V.
The tubular design is suited to trace heating installations where a compact connection enclosure is required.
Compact Power and Splice Connections
The SOLCO SP-2JB Connectatube is designed to accommodate trace heating cable connections using its two-entry tubular enclosure.
SOLCO specifies sufficient terminals for either a single power-to-heater connection or a heating cable splice connection.
The internal terminal arrangement is designed to make the correct wiring orientation easier to identify.
Connection Arrangements
Connect one suitable power supply to one compatible trace heating circuit.
Connect one compatible heating cable circuit to another using the manufacturer's splice arrangement.
SOLCO also lists power, end and splice connections among the applications for the SP-2JB.
The correct connection configuration and any required termination components should be selected according to the manufacturer's installation instructions.
Key Features and Benefits
Compact M25 configuration with an outside diameter of just 32mm.
Manufacturer-specified IP68 protection rating for the correctly assembled enclosure.
Designed for single power-to-heater or heater-to-heater connection arrangements.
Internal terminal arrangement with a published rating of 32A and 450V.
Tough weatherproof construction with manufacturer-stated environmental resistance.
Designed for power, end and splice connections in suitable SOLCO heating cable systems.
SOLCO SP-2JB Technical Specifications
| Specification | SP-2JB Connectatube |
|---|---|
| Manufacturer | SOLCO Pyroelec |
| Manufacturer Model | SP-2JB |
| Product Name | Connectatube |
| Product Type | Tubular Trace Heating Junction Box |
| Nominal Tubular Size | M25 |
| Outside Diameter | 32mm |
| Number of Cable Entries | 2 |
| Enclosure Material | PA66 / TPE |
| Ingress Protection Rating | IP68 |
| Minimum Temperature Rating | -40°C |
| Maximum Temperature Rating | +125°C |
| Terminal System | 3-Pole Terminals |
| Terminal Current Rating | 32A |
| Terminal Voltage Rating | 450V |
| Connection Arrangements | Power, End and Splice |
| Primary Application | SOLCO Pyroelec Trace Heating Connections |
Technical specifications are based on SOLCO's published SP-2JB product information. Enclosure temperature limits and terminal ratings should not be interpreted as the operating limits of a complete trace heating circuit.
Installation and Cable Selection
The SP-2JB is designed for use with SOLCO Pyroelec trace heating cable systems. Selection should be based on the required connection arrangement and the cable being installed.
- Confirm that the SP-2JB is suitable for the intended heating cable type.
- Determine whether a power, end or splice connection is required.
- Verify the required cable entry sealing and termination components.
- Confirm the electrical circuit requirements against the 32A / 450V terminal ratings.
- Follow the manufacturer's assembly and installation instructions to achieve the specified protection rating.
Installation Note: Electrical connections should be completed by suitably qualified personnel. Cable compatibility and installation requirements should be confirmed before use.
SP-2JB Connectatube or SP-3JB Connectabox?
SOLCO offers different junction box arrangements to suit the number of cable entries required.
| Feature | SP-2JB | SP-3JB |
|---|---|---|
| Design | Tubular | T-Shaped |
| Cable Entries | 2 | 3 |
| IP Rating | IP68 | IP65 |
| Typical Arrangement | Power to one heater or splice | Power to two heaters or tee connection |
Choose the junction box according to the required connection layout and manufacturer installation requirements.
Complete Your Trace Heating Installation
Explore additional SOLCO connection products and trace heating accessories available from Insulation & More.
Need Trace Heating Connection Accessories?
From compact junction boxes and termination components to heating cables and temperature controllers, Insulation & More supplies products for commercial trace heating projects.
Contact our team for product enquiries, trade pricing and larger project requirements.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.