Free shipping for orders over £250! (Exc. VAT)

First Time Customer Discount

Get 5% off your first order! T&C

FIRSTFIVE

SmSR1002-CX Self-Regulating Snow Melting Cable – 100W/m

£19.00
Unit price£19.00 / m
Shipping calculated at checkout.


Human score    Trustpilot Stars    number of reviews    Trustpilot Logo

Description

Estimated lead time: 12 weeks
Need it sooner? Contact our team before ordering.

SOLCO SmSR1002-CX Self-Regulating Snow Melting Heating Cable – 100W/m

The SOLCO SmSR1002-CX Self-Regulating Heating Cable is a high-output electric trace heating cable designed for snow melting and anti-icing in concrete pavements, ramps and access roads.

Specifically developed for direct installation within concrete, SmSR provides a robust heating solution for pedestrian and vehicle access areas exposed to freezing winter conditions.

Rated at 100W/m at 0°C in ice-and-water conditions, the 230V cable automatically adjusts its heat output in response to surrounding temperature changes.

100W/m At 0°C in Ice and Water
230V AC Supply
80°C Max. Maintain Temperature
135°C Max. Exposure, Power Off

Snow Melting and Anti-Icing for Concrete Surfaces

Snow and ice accumulation on access roads, pedestrian pavements and vehicle ramps can create hazardous surface conditions during winter weather.

SOLCO SmSR is designed to provide distributed electric heating within concrete surfaces, helping reduce snow accumulation and ice formation when installed as part of a correctly designed de-icing system.

Its high-output construction makes it particularly suitable for commercial and infrastructure projects requiring dependable surface heating.

Designed for Direct Installation in Concrete

SmSR is specifically manufactured for direct burial in concrete, making it suitable for integrated heating systems within pavements, access roads and car park ramps.

How SOLCO SmSR Self-Regulating Heating Cable Works

SmSR incorporates a self-regulating heating element that changes its electrical resistance in response to temperature.

When temperatures decrease, the cable increases its heat output. As the surrounding temperature rises, the heat output reduces automatically.

Individual sections of the cable respond to local temperature conditions, helping deliver variable heat output throughout the installation.

This technology is particularly useful for outdoor surface heating systems, where temperature conditions can vary across different areas of the same pavement or ramp.

Key Features and Benefits

High-Output Snow Melting

Provides 100W/m at 0°C in ice-and-water conditions for demanding pavement heating applications.

Concrete Installation

Specifically designed for direct burial in concrete pavements, roads and ramps.

Self-Regulating Technology

Automatically adjusts heat output in response to local temperature changes.

Overlap-Tolerant Design

Manufacturer-designed to resist burning or overheating when overlapped under specified conditions.

Cut-to-Length Flexibility

Can be cut to suit installation requirements, subject to maximum circuit lengths and correct termination.

Robust Construction

Manufactured for demanding installation conditions and high-temperature exposure.

XLEVA Outer Jacket

Features the manufacturer's specified XLEVA outer jacket construction.

Soft Power Switching

Manufacturer-designed power switching supports operating efficiency and cable service life.

Typical Applications

Car Park Ramps

Anti-icing systems for sloped vehicle entrances and commercial car park access areas.

Concrete Pavements

Snow melting for suitable pedestrian routes, walkways and paved areas.

Commercial Entrances

Surface heating for entrances to offices, public buildings and commercial premises.

Access Roads

De-icing installations for roads serving suitable commercial developments.

Holiday Resorts

Snow melting for entrance roads serving resorts and golf courses.

Infrastructure Projects

Manufacturer-listed applications include bridges and airport infrastructure.

Heating Output and Performance

SOLCO SmSR1002-CX has two published heat output ratings depending on the surrounding ice and moisture conditions.

Test Conditions Rated Heat Output
0°C – Ice and Water 100W/m
0°C – Ice 120W/m

These ratings describe the same SmSR1002-CX cable under different conditions. They are not separate heating cable variants.

Selecting the Correct Heating Layout

The required cable spacing and total installed heating capacity depend on the surface construction, expected weather conditions, desired performance and calculated heat requirement.

SOLCO describes typical system design outputs of approximately 300W/m² or greater for snow melting and approximately 150W/m² for de-icing applications. These are application guidance figures rather than universal installation requirements.

SOLCO SmSR1002-CX Technical Specifications

Specification SmSR1002-CX
Manufacturer SOLCO Pyroelec
Product Model SmSR1002-CX
Cable Type Self-Regulating Heating Cable
Primary Application Pavement Snow Melting and Anti-Icing
Rated Output – Ice and Water 100W/m at 0°C
Rated Output – Ice 120W/m at 0°C
Applied Voltage 230V AC
Voltage Class 200–240V AC
Maximum Maintain Temperature 80°C (Power On)
Maximum Continuous Exposure 135°C (Power Off)
Bus Wire ASTM B355 Class 2 Nickel-Plated Copper, 14 AWG
Approximate Dimensions 18.6 ± 0.2mm × 9.4 ± 0.2mm
Outer Jacket XLEVA
Installation Designed for Direct Burial in Concrete

Technical values are based on SOLCO's published SmSR1002-CX specifications. Confirm circuit lengths, breaker ratings, cable spacing and installation requirements using the latest manufacturer guidance.

Installation and System Requirements

SOLCO SmSR1002-CX should be installed as part of a properly designed pavement snow melting or anti-icing system.

Installation Considerations
  • Determine the total surface area and required heating output per square metre.
  • Calculate cable spacing and the required cable length for the installation.
  • Plan the cable layout and installation depth according to the concrete surface construction.
  • Use suitable temperature, snow and moisture sensing controls.
  • Select compatible connections, end seals and fixing accessories.
  • Verify maximum circuit lengths and protective device ratings against SOLCO's technical data.
  • Protect the heating cable against installation damage during concrete placement.
  • Follow the manufacturer's testing and commissioning procedures.

Installation Note: Electrical installation and termination must be carried out by suitably qualified personnel in accordance with manufacturer instructions and applicable regulations.

Complete Your Snow Melting Installation

Insulation & More supplies trace heating products and supports enquiries for associated controls and installation accessories.

INSULATION & MORE | COMMERCIAL SUPPLY

Planning a Commercial Snow Melting or De-Icing Project?

Whether you need heating cable for a car park ramp, commercial entrance, access road or concrete pavement, our team can assist with product enquiries and project quotations.

We support M&E contractors, electrical installers and commercial buyers with trace heating cables, controls and installation accessories.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options

Payment & Security

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Commercial, commercial use, de-icing, energy-efficient, heating cable
Solco

SmSR1002-CX Self-Regulating Snow Melting Cable – 100W/m

£19.00
Unit price£19.00 / m
Estimated lead time: 12 weeks
Need it sooner? Contact our team before ordering.

SOLCO SmSR1002-CX Self-Regulating Snow Melting Heating Cable – 100W/m

The SOLCO SmSR1002-CX Self-Regulating Heating Cable is a high-output electric trace heating cable designed for snow melting and anti-icing in concrete pavements, ramps and access roads.

Specifically developed for direct installation within concrete, SmSR provides a robust heating solution for pedestrian and vehicle access areas exposed to freezing winter conditions.

Rated at 100W/m at 0°C in ice-and-water conditions, the 230V cable automatically adjusts its heat output in response to surrounding temperature changes.

100W/m At 0°C in Ice and Water
230V AC Supply
80°C Max. Maintain Temperature
135°C Max. Exposure, Power Off

Snow Melting and Anti-Icing for Concrete Surfaces

Snow and ice accumulation on access roads, pedestrian pavements and vehicle ramps can create hazardous surface conditions during winter weather.

SOLCO SmSR is designed to provide distributed electric heating within concrete surfaces, helping reduce snow accumulation and ice formation when installed as part of a correctly designed de-icing system.

Its high-output construction makes it particularly suitable for commercial and infrastructure projects requiring dependable surface heating.

Designed for Direct Installation in Concrete

SmSR is specifically manufactured for direct burial in concrete, making it suitable for integrated heating systems within pavements, access roads and car park ramps.

How SOLCO SmSR Self-Regulating Heating Cable Works

SmSR incorporates a self-regulating heating element that changes its electrical resistance in response to temperature.

When temperatures decrease, the cable increases its heat output. As the surrounding temperature rises, the heat output reduces automatically.

Individual sections of the cable respond to local temperature conditions, helping deliver variable heat output throughout the installation.

This technology is particularly useful for outdoor surface heating systems, where temperature conditions can vary across different areas of the same pavement or ramp.

Key Features and Benefits

High-Output Snow Melting

Provides 100W/m at 0°C in ice-and-water conditions for demanding pavement heating applications.

Concrete Installation

Specifically designed for direct burial in concrete pavements, roads and ramps.

Self-Regulating Technology

Automatically adjusts heat output in response to local temperature changes.

Overlap-Tolerant Design

Manufacturer-designed to resist burning or overheating when overlapped under specified conditions.

Cut-to-Length Flexibility

Can be cut to suit installation requirements, subject to maximum circuit lengths and correct termination.

Robust Construction

Manufactured for demanding installation conditions and high-temperature exposure.

XLEVA Outer Jacket

Features the manufacturer's specified XLEVA outer jacket construction.

Soft Power Switching

Manufacturer-designed power switching supports operating efficiency and cable service life.

Typical Applications

Car Park Ramps

Anti-icing systems for sloped vehicle entrances and commercial car park access areas.

Concrete Pavements

Snow melting for suitable pedestrian routes, walkways and paved areas.

Commercial Entrances

Surface heating for entrances to offices, public buildings and commercial premises.

Access Roads

De-icing installations for roads serving suitable commercial developments.

Holiday Resorts

Snow melting for entrance roads serving resorts and golf courses.

Infrastructure Projects

Manufacturer-listed applications include bridges and airport infrastructure.

Heating Output and Performance

SOLCO SmSR1002-CX has two published heat output ratings depending on the surrounding ice and moisture conditions.

Test Conditions Rated Heat Output
0°C – Ice and Water 100W/m
0°C – Ice 120W/m

These ratings describe the same SmSR1002-CX cable under different conditions. They are not separate heating cable variants.

Selecting the Correct Heating Layout

The required cable spacing and total installed heating capacity depend on the surface construction, expected weather conditions, desired performance and calculated heat requirement.

SOLCO describes typical system design outputs of approximately 300W/m² or greater for snow melting and approximately 150W/m² for de-icing applications. These are application guidance figures rather than universal installation requirements.

SOLCO SmSR1002-CX Technical Specifications

Specification SmSR1002-CX
Manufacturer SOLCO Pyroelec
Product Model SmSR1002-CX
Cable Type Self-Regulating Heating Cable
Primary Application Pavement Snow Melting and Anti-Icing
Rated Output – Ice and Water 100W/m at 0°C
Rated Output – Ice 120W/m at 0°C
Applied Voltage 230V AC
Voltage Class 200–240V AC
Maximum Maintain Temperature 80°C (Power On)
Maximum Continuous Exposure 135°C (Power Off)
Bus Wire ASTM B355 Class 2 Nickel-Plated Copper, 14 AWG
Approximate Dimensions 18.6 ± 0.2mm × 9.4 ± 0.2mm
Outer Jacket XLEVA
Installation Designed for Direct Burial in Concrete

Technical values are based on SOLCO's published SmSR1002-CX specifications. Confirm circuit lengths, breaker ratings, cable spacing and installation requirements using the latest manufacturer guidance.

Installation and System Requirements

SOLCO SmSR1002-CX should be installed as part of a properly designed pavement snow melting or anti-icing system.

Installation Considerations
  • Determine the total surface area and required heating output per square metre.
  • Calculate cable spacing and the required cable length for the installation.
  • Plan the cable layout and installation depth according to the concrete surface construction.
  • Use suitable temperature, snow and moisture sensing controls.
  • Select compatible connections, end seals and fixing accessories.
  • Verify maximum circuit lengths and protective device ratings against SOLCO's technical data.
  • Protect the heating cable against installation damage during concrete placement.
  • Follow the manufacturer's testing and commissioning procedures.

Installation Note: Electrical installation and termination must be carried out by suitably qualified personnel in accordance with manufacturer instructions and applicable regulations.

Complete Your Snow Melting Installation

Insulation & More supplies trace heating products and supports enquiries for associated controls and installation accessories.

INSULATION & MORE | COMMERCIAL SUPPLY

Planning a Commercial Snow Melting or De-Icing Project?

Whether you need heating cable for a car park ramp, commercial entrance, access road or concrete pavement, our team can assist with product enquiries and project quotations.

We support M&E contractors, electrical installers and commercial buyers with trace heating cables, controls and installation accessories.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options
View product