Free shipping for orders over £250! (Exc. VAT)

First Time Customer Discount

Get 5% off your first order! T&C

FIRSTFIVE

HWS-P Self-Regulating Hot Water Trace Heating Cable

£8.60
Unit price£8.60 / m
Shipping calculated at checkout.


Human score    Trustpilot Stars    number of reviews    Trustpilot Logo

Description

SOLCO HWS-P Self-Regulating Hot Water Trace Heating Cable

The SOLCO HWS-P Self-Regulating Heating Cable is designed for temperature maintenance of domestic and commercial hot water pipework, with the added capability to support periodic thermal disinfection.

Designed to maintain pipework temperatures between 40°C and 70°C, HWS-P provides an electric trace heating solution for hot water distribution systems requiring controlled temperature maintenance.

With a nominal output of 9.5W/m at 70°C, the cable uses self-regulating technology to adjust heat output along its length in response to local temperature conditions.

40–70°C Pipework Maintenance Range
9.5W/m Nominal Output at 70°C
80°C Max. Maintain Temperature
100°C Max. Intermittent Exposure

Hot Water Temperature Maintenance with Periodic Thermal Disinfection

The SOLCO HWS-P Self-Regulating Heating Cable is designed to maintain hot water pipework temperatures between 40°C and 70°C, providing reliable temperature maintenance for domestic and commercial hot water distribution systems.

Unlike standard hot water trace heating cables, HWS-P also supports periodic thermal disinfection, helping manage the risk of Legionella bacteria within appropriately designed hot water systems.

Its self-regulating technology automatically adjusts heat output in response to temperature changes, supporting consistent hot water availability and effective temperature maintenance.

Installation Note: Periodic thermal disinfection should be managed through suitable temperature controls and carried out in accordance with the manufacturer's guidance and applicable water hygiene requirements.

How SOLCO HWS-P Works

The HWS-P heating cable incorporates self-regulating technology that responds to the temperature surrounding each section of cable.

When pipe temperatures fall, the heating element increases its output. As temperatures rise, heat output decreases.

This independent heat output control helps the cable respond to temperature variations along a hot water pipework installation.

When correctly specified with suitable temperature controls and pipe insulation, HWS-P can maintain the required pipework temperatures without the need for a conventional recirculation arrangement in suitably designed systems.

Key Features and Benefits

40–70°C Maintenance Range

Designed for hot water pipework requiring temperature maintenance across the specified operating range.

Periodic Disinfection Capability

Supports appropriately designed thermal disinfection procedures as part of a wider water hygiene management strategy.

Self-Regulating Heat Output

Automatically varies heat output according to local temperature conditions along the cable.

Alternative to Recirculation

Can eliminate the need for hot water return pipework and recirculation pumps in suitable system designs.

Hot Water Availability

Helps maintain temperatures throughout the distribution pipework, reducing waiting times for hot water at outlets.

Soft Power Switching

Manufacturer-designed switching characteristics help improve efficiency and contribute to a longer cable service life.

Typical Applications

Commercial Hot Water Systems

Temperature maintenance in suitable commercial building-services installations.

Hotels and Accommodation

Hot water distribution systems requiring controlled temperature maintenance.

Healthcare and Public Buildings

Specified hot water systems incorporating temperature control and water hygiene management procedures.

Residential Developments

Hot water pipework within suitable multi-property and domestic installations.

Building Refurbishments

Suitable replacement or alternative arrangements to conventional hot water recirculation pipework.

M&E Installations

Commercial and domestic mechanical-services projects requiring hot water temperature maintenance.

SOLCO HWS-P Technical Specifications

Specification HWS-P
Manufacturer SOLCO Pyroelec
Product Model HWS-P
Cable Type Self-Regulating Hot Water Heating Cable
Designed Maintenance Range 40°C to 70°C
Nominal Heat Output 9.5W/m at 70°C
Manufacturer Voltage Availability 24–240V AC
Maximum Maintain Temperature 80°C (Power On)
Maximum Intermittent Exposure 100°C (Power Off)
Approximate Cable Dimensions 12.8mm x 5.5mm
Bus Wire 16 AWG Nickel-Plated Copper
Maximum Earth Braid Resistance 18.2 Ohm/km
Primary Application Hot Water Temperature Maintenance with Periodic Thermal Disinfection Capability

Manufacturer specifications apply to the HWS-P series. Confirm the supplied voltage configuration, maximum circuit length and electrical protection requirements before installation.

Installation and System Requirements

SOLCO HWS-P must be specified as part of a complete hot water temperature maintenance system.

Installation Considerations
  • Confirm the required normal maintaining temperature and disinfection operating requirements.
  • Calculate pipework heat loss based on pipe diameter, insulation thickness and installation conditions.
  • Specify suitable controls, monitoring and protective devices for the intended operating temperatures.
  • Use compatible power connections, end seals, junction boxes and fixing accessories.
  • Install appropriate thermal insulation over the completed trace heating system.
  • Verify maximum circuit lengths and circuit breaker selection using SOLCO's latest technical documentation.
  • Ensure the complete hot water installation incorporates appropriate water hygiene and scalding risk controls.

Important: Installation must be carried out by suitably qualified personnel in accordance with manufacturer guidance and applicable electrical and water system requirements.

HWS-P or HWS-R: Which Cable Do You Need?

SOLCO manufactures two HWS heating cables for different hot water maintenance requirements.

Feature HWS-R HWS-P
Maintenance Range 50–60°C 40–70°C
Nominal Heat Output 9W/m at 55°C 9.5W/m at 70°C
Primary Function Standard hot water maintenance Hot water maintenance with periodic disinfection capability
Looking for Standard Hot Water Maintenance?

Explore SOLCO HWS-R for hot water temperature maintenance between 50°C and 60°C.

View HWS-R Cable

Complete Your Hot Water Trace Heating System

Insulation & More supplies associated heating controls, connection accessories and pipe insulation materials for commercial installations.

INSULATION & MORE | TRADE SUPPLY

Specifying Hot Water Trace Heating for a Commercial Project?

Need HWS-P heating cable for a commercial installation, or assistance selecting the associated controls, accessories and insulation?

Insulation & More supports plumbers, M&E contractors, facilities management teams and commercial buyers with product enquiries and project quotations.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options

Need advice before ordering? Call 01792 209987 or email info@insulation-more.co.uk .


Payment & Security

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Solco

HWS-P Self-Regulating Hot Water Trace Heating Cable

£8.60
Unit price£8.60 / m

SOLCO HWS-P Self-Regulating Hot Water Trace Heating Cable

The SOLCO HWS-P Self-Regulating Heating Cable is designed for temperature maintenance of domestic and commercial hot water pipework, with the added capability to support periodic thermal disinfection.

Designed to maintain pipework temperatures between 40°C and 70°C, HWS-P provides an electric trace heating solution for hot water distribution systems requiring controlled temperature maintenance.

With a nominal output of 9.5W/m at 70°C, the cable uses self-regulating technology to adjust heat output along its length in response to local temperature conditions.

40–70°C Pipework Maintenance Range
9.5W/m Nominal Output at 70°C
80°C Max. Maintain Temperature
100°C Max. Intermittent Exposure

Hot Water Temperature Maintenance with Periodic Thermal Disinfection

The SOLCO HWS-P Self-Regulating Heating Cable is designed to maintain hot water pipework temperatures between 40°C and 70°C, providing reliable temperature maintenance for domestic and commercial hot water distribution systems.

Unlike standard hot water trace heating cables, HWS-P also supports periodic thermal disinfection, helping manage the risk of Legionella bacteria within appropriately designed hot water systems.

Its self-regulating technology automatically adjusts heat output in response to temperature changes, supporting consistent hot water availability and effective temperature maintenance.

Installation Note: Periodic thermal disinfection should be managed through suitable temperature controls and carried out in accordance with the manufacturer's guidance and applicable water hygiene requirements.

How SOLCO HWS-P Works

The HWS-P heating cable incorporates self-regulating technology that responds to the temperature surrounding each section of cable.

When pipe temperatures fall, the heating element increases its output. As temperatures rise, heat output decreases.

This independent heat output control helps the cable respond to temperature variations along a hot water pipework installation.

When correctly specified with suitable temperature controls and pipe insulation, HWS-P can maintain the required pipework temperatures without the need for a conventional recirculation arrangement in suitably designed systems.

Key Features and Benefits

40–70°C Maintenance Range

Designed for hot water pipework requiring temperature maintenance across the specified operating range.

Periodic Disinfection Capability

Supports appropriately designed thermal disinfection procedures as part of a wider water hygiene management strategy.

Self-Regulating Heat Output

Automatically varies heat output according to local temperature conditions along the cable.

Alternative to Recirculation

Can eliminate the need for hot water return pipework and recirculation pumps in suitable system designs.

Hot Water Availability

Helps maintain temperatures throughout the distribution pipework, reducing waiting times for hot water at outlets.

Soft Power Switching

Manufacturer-designed switching characteristics help improve efficiency and contribute to a longer cable service life.

Typical Applications

Commercial Hot Water Systems

Temperature maintenance in suitable commercial building-services installations.

Hotels and Accommodation

Hot water distribution systems requiring controlled temperature maintenance.

Healthcare and Public Buildings

Specified hot water systems incorporating temperature control and water hygiene management procedures.

Residential Developments

Hot water pipework within suitable multi-property and domestic installations.

Building Refurbishments

Suitable replacement or alternative arrangements to conventional hot water recirculation pipework.

M&E Installations

Commercial and domestic mechanical-services projects requiring hot water temperature maintenance.

SOLCO HWS-P Technical Specifications

Specification HWS-P
Manufacturer SOLCO Pyroelec
Product Model HWS-P
Cable Type Self-Regulating Hot Water Heating Cable
Designed Maintenance Range 40°C to 70°C
Nominal Heat Output 9.5W/m at 70°C
Manufacturer Voltage Availability 24–240V AC
Maximum Maintain Temperature 80°C (Power On)
Maximum Intermittent Exposure 100°C (Power Off)
Approximate Cable Dimensions 12.8mm x 5.5mm
Bus Wire 16 AWG Nickel-Plated Copper
Maximum Earth Braid Resistance 18.2 Ohm/km
Primary Application Hot Water Temperature Maintenance with Periodic Thermal Disinfection Capability

Manufacturer specifications apply to the HWS-P series. Confirm the supplied voltage configuration, maximum circuit length and electrical protection requirements before installation.

Installation and System Requirements

SOLCO HWS-P must be specified as part of a complete hot water temperature maintenance system.

Installation Considerations
  • Confirm the required normal maintaining temperature and disinfection operating requirements.
  • Calculate pipework heat loss based on pipe diameter, insulation thickness and installation conditions.
  • Specify suitable controls, monitoring and protective devices for the intended operating temperatures.
  • Use compatible power connections, end seals, junction boxes and fixing accessories.
  • Install appropriate thermal insulation over the completed trace heating system.
  • Verify maximum circuit lengths and circuit breaker selection using SOLCO's latest technical documentation.
  • Ensure the complete hot water installation incorporates appropriate water hygiene and scalding risk controls.

Important: Installation must be carried out by suitably qualified personnel in accordance with manufacturer guidance and applicable electrical and water system requirements.

HWS-P or HWS-R: Which Cable Do You Need?

SOLCO manufactures two HWS heating cables for different hot water maintenance requirements.

Feature HWS-R HWS-P
Maintenance Range 50–60°C 40–70°C
Nominal Heat Output 9W/m at 55°C 9.5W/m at 70°C
Primary Function Standard hot water maintenance Hot water maintenance with periodic disinfection capability
Looking for Standard Hot Water Maintenance?

Explore SOLCO HWS-R for hot water temperature maintenance between 50°C and 60°C.

View HWS-R Cable

Complete Your Hot Water Trace Heating System

Insulation & More supplies associated heating controls, connection accessories and pipe insulation materials for commercial installations.

INSULATION & MORE | TRADE SUPPLY

Specifying Hot Water Trace Heating for a Commercial Project?

Need HWS-P heating cable for a commercial installation, or assistance selecting the associated controls, accessories and insulation?

Insulation & More supports plumbers, M&E contractors, facilities management teams and commercial buyers with product enquiries and project quotations.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options

Need advice before ordering? Call 01792 209987 or email info@insulation-more.co.uk .

View product