Solco MSR202-CP Self-Regulating Trace Heating Cable

MSR202-CP Heating Cable 20 W/m

MSR202-CP is a Solco self-regulating heating cable rated at 20 W/m at 10°C, designed for commercial and construction trace heating applications.

It is commonly used for freeze protection of low temperature hot water pipework and medium temperature maintenance where the cable, controls, insulation and cladding need to work together as a complete system.

Need Help Checking if MSR202-CP is the Right Cable?

Trace heating cable selection depends on pipe size, pipe material, insulation thickness, ambient temperature, required maintain temperature, controller selection and circuit length. Send us your pipework schedule and we can help check the correct cable, controller, insulation and accessory route.

Call: 01792 209987 Email: info@insulation-more.co.uk

What is MSR202-CP Heating Cable?

MSR202-CP is a 20 W/m conductive polymer self-regulating trace heating cable for freeze protection and medium temperature maintenance.

The cable automatically adjusts its heat output in response to the surrounding temperature. When the pipe or surface gets colder, the cable increases heat output. As the temperature rises, the output reduces.

This self-regulating behaviour helps provide controlled heat along the cable length and reduces the risk of overheating or burnout, even where cable sections overlap during installation.

MSR202-CP can be cut to length on site and should be installed with suitable Solco-compatible termination kits, temperature control, fixing tape, insulation and cladding where required.

Main Benefits

1

20 W/m Self-Regulating Output

Rated at 20 W/m at 10°C, making it suitable for commercial trace heating and medium temperature applications.

2

Overlap Protection

Designed to prevent overheating or burnout, even if cable sections overlap during installation.

3

Cut to Length

Can be cut to suit the required pipe run length, helping reduce waste and improve installation flexibility.

4

Commercial Pipework Use

Designed for commercial and construction industry trace heating applications in non-hazardous locations.

5

Works as a Full System

Used with controllers, junction boxes, termination kits, fixing tape, insulation and cladding.

6

Freeze Protection Support

Suitable for frost protection duties where the system has been correctly designed, insulated and controlled.

Typical Applications

MSR202-CP is used where pipework needs electrical trace heating for freeze protection or medium temperature maintenance.

  • Freeze protection of low temperature hot water pipework
  • LTHW services where the system may be exposed to sub-zero ambient temperatures when not operational
  • Commercial plant rooms, service risers and external pipe runs
  • Medium temperature maintenance on commercial and industrial pipework
  • Water pipeline freeze protection where the system is designed correctly
  • Pipework systems requiring coordinated cable, controller, insulation and cladding selection

MSR202-CP Product Details

This product is MSR202-CP: 20 W/m at 10°C, 200–240 Vac, with FR polyolefin outer jacket.
Specification Details
Product Code MSR202-CP
Product Type Self-regulating trace heating cable
Rated Output 20 W/m at 10°C
Rated Voltage 200–240 Vac
Outer Jacket FR Polyolefin
Application Freeze protection and medium temperature maintenance
Maximum Maintain Temperature 80°C Power ON
Maximum Withstand Temperature 100°C Power OFF
Nominal Cable Dimension Approx. 13.4mm x 5.4mm
Minimum Bending Radius 25mm
Parallel Conductors Nickel plated copper wire, AWG 16 / 1.5mm²
Heating Element Polymeric heating element, HDPE + C/B
Earthing Braided tinned copper wire nickel
Primary Insulation Polyolefin

Maximum Circuit Length Guide

The table below shows the manufacturer’s maximum circuit length guidance for MSR202-CP at 230Vac, based on start-up temperature and Type C circuit breaker size.

Start-Up Temperature 10A 16A 20A 25A 32A 40A
-20°C 36m 58m 73m 91m 108m 108m
0°C 38m 61m 77m 96m 120m 120m
10°C 43m 68m 85m 106m 126m 126m

Guide only. Circuit length depends on system design, start-up temperature, protective device, cable route, control method and installation conditions. Electrical design and commissioning should be completed by competent persons.

Design and Safety Note

Trace heating cable must be selected, installed, tested and commissioned by competent persons in line with the project specification and relevant standards.

MSR202-CP cable selection is not based on cable output alone. Pipe size, pipe material, insulation thickness, ambient temperature, start-up conditions, controller type, protective devices and maximum circuit length all need to be checked before installation.

How to Apply MSR202-CP Trace Heating Cable

Install MSR202-CP as part of a complete system: pipe check, cable fixing, termination, controller setup, insulation, cladding and final testing.

This is a general installation overview only. Always follow the Solco installation instructions, the trace heating design and competent electrical installation practice.

Check the Pipework

Confirm pipe size, pipe material, service temperature, ambient exposure, insulation thickness and required maintain temperature.

Fix the Cable

Install the heating cable to the pipe as specified, typically as a straight trace unless the design states otherwise.

Terminate and Control

Use suitable Solco-compatible termination kits, junction boxes, sensors and temperature controllers.

Insulate and Test

Apply suitable pipe insulation and cladding where required, then test and commission the full trace heating system.

On plastic pipework, or where improved heat transfer is required by the specification, aluminium foil tape may be used over the heating cable before insulation is fitted. Always check the system design before ordering materials.

MSR202-CP should be treated as part of a full trace heating system, including temperature control, cable termination, fixing accessories, insulation and weather protection where required.

Compare Solco Trace Heating Cable Options

MSR202-CP is suitable for LTHW freeze protection and medium temperature maintenance. For cold/chilled water frost protection or hot water temperature maintenance, another Solco cable route may be more suitable.

Placeholder image for MSR202-CP heating cable

MSR202-CP 20 W/m

For LTHW frost protection and medium temperature maintenance where a 20 W/m cable is required.

Current Product

Trace Heating, Insulation, Cladding and Jackets Work Together

Trace heating provides heat, insulation slows heat loss, cladding protects the system, and thermal jackets help insulate valves, flanges and fittings.

A trace heating cable should not be treated as a standalone product. Most pipework systems need the cable to be considered alongside pipe insulation, fixing tape, joint sealing, controller selection, warning labels, testing and external protection.

For exposed pipework, outdoor plant areas or locations where insulation may be damaged or weather-exposed, a suitable cladding route or thermal jacket route should also be considered.

Who is MSR202-CP Cable Ideal For?

  • M&E contractors installing trace heating on commercial pipework
  • Lagging contractors coordinating heating cable, insulation and cladding
  • Facilities teams protecting exposed or unheated services
  • Industrial sites requiring medium temperature maintenance
  • Contractors working on LTHW pipework with frost protection requirements
  • Specifiers who need self-regulating trace heating cable with controller and accessory compatibility

Trace Heating Training and Support

Insulation & More also provides practical trace heating and lagging training for contractors, installers and businesses who want a better understanding of cable preparation, installation, insulation, cladding and system finishing.

This is useful for teams working with commercial pipework, sprinkler pipework, frost protection systems, heating cable accessories and insulation details.

Trace heating and lagging training workshop

Hands-On Training

Practical workshop sessions using real trace heating, insulation and cladding materials.

Trace heating cable preparation training

Trace Heating Skills

Cable preparation, connections, controllers, fixing methods and installation best practice.

Trace heating testing and installation practice

Lagging and Finishing

Training on insulation fitting, reducing gaps, cladding, weatherproofing and professional finishes.

View Trace Heating & Lagging Training

Frequently Asked Questions

What is MSR202-CP heating cable used for?

MSR202-CP is used for freeze protection and medium temperature maintenance on commercial and industrial pipework where a 20 W/m self-regulating trace heating cable is required.

What output is MSR202-CP?

MSR202-CP is rated at 20 W/m at 10°C.

Can MSR202-CP cable be cut to length?

Yes. MSR202-CP can be cut to the required length on site, but it must be terminated correctly using suitable Solco-compatible power connection, splice and end-seal accessories.

Will MSR202-CP overheat if overlapped?

The cable is self-regulating and is designed to prevent overheating or burnout, even when overlapped. The full installation must still follow the approved design and installation instructions.

Does trace heating need insulation?

Yes. Trace heating systems are normally installed with suitable pipe insulation. The insulation reduces heat loss and helps the cable maintain the required pipe temperature efficiently.

Which controller should be used with MSR202-CP?

Controller selection depends on the application. Smart-ECO is commonly used for commercial trace heating control, while Smart-PRO may be selected where additional monitoring or control functionality is required.

Can MSR202-CP be used outdoors?

Outdoor suitability depends on the full system design, terminations, ingress protection, insulation and cladding. Exposed installations should be protected with suitable insulation covering and weatherproof detailing.

What is the difference between MSR, HSR and HWS-R?

MSR202-CP is a 20 W/m medium temperature cable often used for LTHW frost protection. HSR is commonly used for cold and chilled water frost protection. HWS-R is used for hot water temperature maintenance.

Send Us Your Trace Heating Requirement

If you are not sure whether MSR202-CP is the correct cable, send us the pipe size, pipe material, location, service temperature, insulation thickness, required maintain temperature, circuit length and any specification notes.

Our team can help you compare MSR202-CP, HSR, HWS-R, controllers, junction boxes, insulation, cladding, thermal jackets and accessories for your project.

System Support:
Help with trace heating cable, controller, insulation and cladding routes.
Commercial Focus:
Products for contractors, facilities teams, M&E projects and industrial sites.
Training Available:
Trace heating and lagging training for installers and businesses.

Phone: 01792 209987
Email: info@insulation-more.co.uk
Contact Page: insulation-more.co.uk/pages/contact

Shop More from Insulation & More

Explore related insulation, trace heating, cladding and accessory collections for domestic, commercial and industrial projects.


Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Solco Pyroelec

MSR202-CP Heating Cable 20 W/m

£9.52

Solco MSR202-CP Self-Regulating Trace Heating Cable

MSR202-CP Heating Cable 20 W/m

MSR202-CP is a Solco self-regulating heating cable rated at 20 W/m at 10°C, designed for commercial and construction trace heating applications.

It is commonly used for freeze protection of low temperature hot water pipework and medium temperature maintenance where the cable, controls, insulation and cladding need to work together as a complete system.

Need Help Checking if MSR202-CP is the Right Cable?

Trace heating cable selection depends on pipe size, pipe material, insulation thickness, ambient temperature, required maintain temperature, controller selection and circuit length. Send us your pipework schedule and we can help check the correct cable, controller, insulation and accessory route.

Call: 01792 209987 Email: info@insulation-more.co.uk

What is MSR202-CP Heating Cable?

MSR202-CP is a 20 W/m conductive polymer self-regulating trace heating cable for freeze protection and medium temperature maintenance.

The cable automatically adjusts its heat output in response to the surrounding temperature. When the pipe or surface gets colder, the cable increases heat output. As the temperature rises, the output reduces.

This self-regulating behaviour helps provide controlled heat along the cable length and reduces the risk of overheating or burnout, even where cable sections overlap during installation.

MSR202-CP can be cut to length on site and should be installed with suitable Solco-compatible termination kits, temperature control, fixing tape, insulation and cladding where required.

Main Benefits

1

20 W/m Self-Regulating Output

Rated at 20 W/m at 10°C, making it suitable for commercial trace heating and medium temperature applications.

2

Overlap Protection

Designed to prevent overheating or burnout, even if cable sections overlap during installation.

3

Cut to Length

Can be cut to suit the required pipe run length, helping reduce waste and improve installation flexibility.

4

Commercial Pipework Use

Designed for commercial and construction industry trace heating applications in non-hazardous locations.

5

Works as a Full System

Used with controllers, junction boxes, termination kits, fixing tape, insulation and cladding.

6

Freeze Protection Support

Suitable for frost protection duties where the system has been correctly designed, insulated and controlled.

Typical Applications

MSR202-CP is used where pipework needs electrical trace heating for freeze protection or medium temperature maintenance.

  • Freeze protection of low temperature hot water pipework
  • LTHW services where the system may be exposed to sub-zero ambient temperatures when not operational
  • Commercial plant rooms, service risers and external pipe runs
  • Medium temperature maintenance on commercial and industrial pipework
  • Water pipeline freeze protection where the system is designed correctly
  • Pipework systems requiring coordinated cable, controller, insulation and cladding selection

MSR202-CP Product Details

This product is MSR202-CP: 20 W/m at 10°C, 200–240 Vac, with FR polyolefin outer jacket.
Specification Details
Product Code MSR202-CP
Product Type Self-regulating trace heating cable
Rated Output 20 W/m at 10°C
Rated Voltage 200–240 Vac
Outer Jacket FR Polyolefin
Application Freeze protection and medium temperature maintenance
Maximum Maintain Temperature 80°C Power ON
Maximum Withstand Temperature 100°C Power OFF
Nominal Cable Dimension Approx. 13.4mm x 5.4mm
Minimum Bending Radius 25mm
Parallel Conductors Nickel plated copper wire, AWG 16 / 1.5mm²
Heating Element Polymeric heating element, HDPE + C/B
Earthing Braided tinned copper wire nickel
Primary Insulation Polyolefin

Maximum Circuit Length Guide

The table below shows the manufacturer’s maximum circuit length guidance for MSR202-CP at 230Vac, based on start-up temperature and Type C circuit breaker size.

Start-Up Temperature 10A 16A 20A 25A 32A 40A
-20°C 36m 58m 73m 91m 108m 108m
0°C 38m 61m 77m 96m 120m 120m
10°C 43m 68m 85m 106m 126m 126m

Guide only. Circuit length depends on system design, start-up temperature, protective device, cable route, control method and installation conditions. Electrical design and commissioning should be completed by competent persons.

Design and Safety Note

Trace heating cable must be selected, installed, tested and commissioned by competent persons in line with the project specification and relevant standards.

MSR202-CP cable selection is not based on cable output alone. Pipe size, pipe material, insulation thickness, ambient temperature, start-up conditions, controller type, protective devices and maximum circuit length all need to be checked before installation.

How to Apply MSR202-CP Trace Heating Cable

Install MSR202-CP as part of a complete system: pipe check, cable fixing, termination, controller setup, insulation, cladding and final testing.

This is a general installation overview only. Always follow the Solco installation instructions, the trace heating design and competent electrical installation practice.

Check the Pipework

Confirm pipe size, pipe material, service temperature, ambient exposure, insulation thickness and required maintain temperature.

Fix the Cable

Install the heating cable to the pipe as specified, typically as a straight trace unless the design states otherwise.

Terminate and Control

Use suitable Solco-compatible termination kits, junction boxes, sensors and temperature controllers.

Insulate and Test

Apply suitable pipe insulation and cladding where required, then test and commission the full trace heating system.

On plastic pipework, or where improved heat transfer is required by the specification, aluminium foil tape may be used over the heating cable before insulation is fitted. Always check the system design before ordering materials.

MSR202-CP should be treated as part of a full trace heating system, including temperature control, cable termination, fixing accessories, insulation and weather protection where required.

Compare Solco Trace Heating Cable Options

MSR202-CP is suitable for LTHW freeze protection and medium temperature maintenance. For cold/chilled water frost protection or hot water temperature maintenance, another Solco cable route may be more suitable.

Placeholder image for MSR202-CP heating cable

MSR202-CP 20 W/m

For LTHW frost protection and medium temperature maintenance where a 20 W/m cable is required.

Current Product

Trace Heating, Insulation, Cladding and Jackets Work Together

Trace heating provides heat, insulation slows heat loss, cladding protects the system, and thermal jackets help insulate valves, flanges and fittings.

A trace heating cable should not be treated as a standalone product. Most pipework systems need the cable to be considered alongside pipe insulation, fixing tape, joint sealing, controller selection, warning labels, testing and external protection.

For exposed pipework, outdoor plant areas or locations where insulation may be damaged or weather-exposed, a suitable cladding route or thermal jacket route should also be considered.

Who is MSR202-CP Cable Ideal For?

  • M&E contractors installing trace heating on commercial pipework
  • Lagging contractors coordinating heating cable, insulation and cladding
  • Facilities teams protecting exposed or unheated services
  • Industrial sites requiring medium temperature maintenance
  • Contractors working on LTHW pipework with frost protection requirements
  • Specifiers who need self-regulating trace heating cable with controller and accessory compatibility

Trace Heating Training and Support

Insulation & More also provides practical trace heating and lagging training for contractors, installers and businesses who want a better understanding of cable preparation, installation, insulation, cladding and system finishing.

This is useful for teams working with commercial pipework, sprinkler pipework, frost protection systems, heating cable accessories and insulation details.

Trace heating and lagging training workshop

Hands-On Training

Practical workshop sessions using real trace heating, insulation and cladding materials.

Trace heating cable preparation training

Trace Heating Skills

Cable preparation, connections, controllers, fixing methods and installation best practice.

Trace heating testing and installation practice

Lagging and Finishing

Training on insulation fitting, reducing gaps, cladding, weatherproofing and professional finishes.

View Trace Heating & Lagging Training

Frequently Asked Questions

What is MSR202-CP heating cable used for?

MSR202-CP is used for freeze protection and medium temperature maintenance on commercial and industrial pipework where a 20 W/m self-regulating trace heating cable is required.

What output is MSR202-CP?

MSR202-CP is rated at 20 W/m at 10°C.

Can MSR202-CP cable be cut to length?

Yes. MSR202-CP can be cut to the required length on site, but it must be terminated correctly using suitable Solco-compatible power connection, splice and end-seal accessories.

Will MSR202-CP overheat if overlapped?

The cable is self-regulating and is designed to prevent overheating or burnout, even when overlapped. The full installation must still follow the approved design and installation instructions.

Does trace heating need insulation?

Yes. Trace heating systems are normally installed with suitable pipe insulation. The insulation reduces heat loss and helps the cable maintain the required pipe temperature efficiently.

Which controller should be used with MSR202-CP?

Controller selection depends on the application. Smart-ECO is commonly used for commercial trace heating control, while Smart-PRO may be selected where additional monitoring or control functionality is required.

Can MSR202-CP be used outdoors?

Outdoor suitability depends on the full system design, terminations, ingress protection, insulation and cladding. Exposed installations should be protected with suitable insulation covering and weatherproof detailing.

What is the difference between MSR, HSR and HWS-R?

MSR202-CP is a 20 W/m medium temperature cable often used for LTHW frost protection. HSR is commonly used for cold and chilled water frost protection. HWS-R is used for hot water temperature maintenance.

Send Us Your Trace Heating Requirement

If you are not sure whether MSR202-CP is the correct cable, send us the pipe size, pipe material, location, service temperature, insulation thickness, required maintain temperature, circuit length and any specification notes.

Our team can help you compare MSR202-CP, HSR, HWS-R, controllers, junction boxes, insulation, cladding, thermal jackets and accessories for your project.

System Support:
Help with trace heating cable, controller, insulation and cladding routes.
Commercial Focus:
Products for contractors, facilities teams, M&E projects and industrial sites.
Training Available:
Trace heating and lagging training for installers and businesses.

Phone: 01792 209987
Email: info@insulation-more.co.uk
Contact Page: insulation-more.co.uk/pages/contact

Shop More from Insulation & More

Explore related insulation, trace heating, cladding and accessory collections for domestic, commercial and industrial projects.

View product