Free shipping for orders over £250! (Exc. VAT)

First Time Customer Discount

Get 5% off your first order! T&C

FIRSTFIVE

IcSR(e)40 2-CV Self-Regulating Roof and Gutter De-Icing Cable – 40W/m

£8.06
Unit price£8.06 / m
Shipping calculated at checkout.


Human score    Trustpilot Stars    number of reviews    Trustpilot Logo

Description

Estimated lead time: 12 weeks
Need it sooner? Contact our team before ordering.

SOLCO IcSR(e)40 2-CV Self-Regulating Roof and Gutter De-Icing Cable

The SOLCO IcSR(e)40 Self-Regulating Heating Cable is designed for snow melting, ice prevention and frost protection in roof drainage and outdoor installations.

With a rated output of 40W/m at 0°C in ice and water, the cable is particularly suited to roofs, gutters, downpipes and external drainage systems exposed to freezing winter conditions.

Its self-regulating heating technology automatically adjusts heat output according to surrounding temperatures, helping maintain effective drainage routes and reduce ice accumulation.

40W/m Rated at 0°C in Ice and Water
80°C Max. Maintain Temperature
100°C Max. Exposure, Power Off
13.4mm Approximate Cable Width

Roof, Gutter and Downpipe De-Icing

During winter, snow accumulating on roofs can begin to melt due to sunlight or heat escaping from a building.

When this meltwater reaches colder gutters or downpipes, it can refreeze and form ice blockages that prevent water from draining properly.

Ice build-up can cause overflowing gutters, icicle formation and potential damage to roofing and drainage components.

Designed for Outdoor Ice Prevention

SOLCO IcSR(e)40 provides a self-regulating electric heating solution for suitable roof edges, gutters and drainage systems, helping reduce ice formation during freezing weather.

How SOLCO IcSR(e) Self-Regulating Cable Works

SOLCO IcSR(e) uses a self-regulating heating element that responds to changes in surrounding temperature.

At lower temperatures, the cable produces more heat. As temperatures rise, its heat output decreases automatically.

Different sections of cable can respond independently to their local conditions, helping provide the required heating along exposed drainage runs.

The cable's flexible, flat construction allows it to follow complex shapes and installation layouts.

Key Features and Benefits

40W/m Heating Output

Rated at 40 watts per metre at 0°C under ice and water conditions.

Self-Regulating Technology

Automatically varies heat output according to surrounding temperature conditions.

Roof and Gutter Protection

Designed to help reduce ice build-up in suitable roof drainage systems.

Outdoor Weather Resistance

Manufacturer-designed for exposure to UV, rain and changing outdoor temperatures.

Overlap-Tolerant Design

Self-regulating construction designed to resist overheating during overlap under specified conditions.

Flexible Flat Profile

Suitable for routing around complex gutter profiles and roof details.

Cut-to-Length Installation

Can be cut to suitable installation lengths, subject to circuit design limits and correct termination.

Soft Power Switching

Manufacturer-designed switching characteristics support efficient operation and cable service life.

Typical Applications

Roof Edges

Ice prevention for suitable roof-edge drainage installations.

Gutters and Downpipes

Helps reduce ice blockages and maintain drainage routes during cold weather.

Commercial Buildings

Snow and ice management for suitable commercial roof installations.

Hotels and Resorts

De-icing and roof drainage protection for suitable resort buildings.

Tall Buildings

Icicle prevention around selected elevated roof and drainage areas.

Infrastructure Projects

Manufacturer-listed applications include appropriate bridges and airport infrastructure.

SOLCO IcSR(e)40 Technical Specifications

Specification IcSR(e)40
Manufacturer SOLCO Pyroelec
Product Series IcSR(e)
Supplier Product Code IcSR(e)40 2-CV
Heating Cable Type Self-Regulating
Nominal Heating Output 40W/m at 0°C (Ice and Water)
Maximum Maintain Temperature 80°C (Power On)
Maximum Continuous Exposure 100°C (Power Off)
Approximate Cable Dimensions 13.4mm x 5.4mm
Bus Wire ASTM B355 Class 2 Nickel-Plated Copper, 16 AWG
Manufacturer Jacket Options P – UV-Resistant Polyolefin; F – Fluoropolymer
Primary Applications Roof and Gutter De-Icing, Snow Melting and Icicle Prevention

Specifications are based on SOLCO's published IcSR(e) technical information. Confirm the supplied jacket, operating voltage and circuit requirements for the 2-CV configuration before installation.

Weather-Resistant Cable Construction

SOLCO offers its IcSR heating cable range with UV-resistant polyolefin and fluoropolymer outer jacket options.

These materials are intended for different outdoor and environmental exposure conditions. The exact outer jacket supplied with the 2-CV configuration should be confirmed against the supplier specification.

Installation and System Requirements

SOLCO IcSR(e)40 should be specified as part of a correctly designed outdoor de-icing system.

Installation Considerations
  • Determine the appropriate cable route through roof edges, gutters and downpipe systems.
  • Select suitable temperature or moisture sensing controls for the installation.
  • Use manufacturer-compatible fixing clips, supports, connection kits and end seals.
  • Confirm the supplied cable jacket is suitable for the operating environment.
  • Ensure external connections and electrical enclosures are appropriately weather protected.
  • Verify maximum circuit lengths, breaker ratings and start-up conditions against SOLCO's technical documentation.
  • Follow manufacturer guidance for routing, termination, testing and commissioning.

Installation Note: Electrical installation must be completed by suitably qualified personnel using appropriate controls and protective devices.

Complete Your De-Icing Installation

Insulation & More supplies a range of trace heating products and associated controls for commercial installations.

INSULATION & MORE | TRADE SUPPLY

Need Roof and Gutter De-Icing for a Commercial Project?

Whether you require an individual cable length or heating cable for a larger roof drainage installation, our team can assist with product selection and project enquiries.

We supply trace heating cables, controllers and associated products for M&E contractors, electrical installers and commercial buyers.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options

Payment & Security

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Commercial heating, use, de-icing, energy efficient, gutter tracing
Solco

IcSR(e)40 2-CV Self-Regulating Roof and Gutter De-Icing Cable – 40W/m

£8.06
Unit price£8.06 / m
Estimated lead time: 12 weeks
Need it sooner? Contact our team before ordering.

SOLCO IcSR(e)40 2-CV Self-Regulating Roof and Gutter De-Icing Cable

The SOLCO IcSR(e)40 Self-Regulating Heating Cable is designed for snow melting, ice prevention and frost protection in roof drainage and outdoor installations.

With a rated output of 40W/m at 0°C in ice and water, the cable is particularly suited to roofs, gutters, downpipes and external drainage systems exposed to freezing winter conditions.

Its self-regulating heating technology automatically adjusts heat output according to surrounding temperatures, helping maintain effective drainage routes and reduce ice accumulation.

40W/m Rated at 0°C in Ice and Water
80°C Max. Maintain Temperature
100°C Max. Exposure, Power Off
13.4mm Approximate Cable Width

Roof, Gutter and Downpipe De-Icing

During winter, snow accumulating on roofs can begin to melt due to sunlight or heat escaping from a building.

When this meltwater reaches colder gutters or downpipes, it can refreeze and form ice blockages that prevent water from draining properly.

Ice build-up can cause overflowing gutters, icicle formation and potential damage to roofing and drainage components.

Designed for Outdoor Ice Prevention

SOLCO IcSR(e)40 provides a self-regulating electric heating solution for suitable roof edges, gutters and drainage systems, helping reduce ice formation during freezing weather.

How SOLCO IcSR(e) Self-Regulating Cable Works

SOLCO IcSR(e) uses a self-regulating heating element that responds to changes in surrounding temperature.

At lower temperatures, the cable produces more heat. As temperatures rise, its heat output decreases automatically.

Different sections of cable can respond independently to their local conditions, helping provide the required heating along exposed drainage runs.

The cable's flexible, flat construction allows it to follow complex shapes and installation layouts.

Key Features and Benefits

40W/m Heating Output

Rated at 40 watts per metre at 0°C under ice and water conditions.

Self-Regulating Technology

Automatically varies heat output according to surrounding temperature conditions.

Roof and Gutter Protection

Designed to help reduce ice build-up in suitable roof drainage systems.

Outdoor Weather Resistance

Manufacturer-designed for exposure to UV, rain and changing outdoor temperatures.

Overlap-Tolerant Design

Self-regulating construction designed to resist overheating during overlap under specified conditions.

Flexible Flat Profile

Suitable for routing around complex gutter profiles and roof details.

Cut-to-Length Installation

Can be cut to suitable installation lengths, subject to circuit design limits and correct termination.

Soft Power Switching

Manufacturer-designed switching characteristics support efficient operation and cable service life.

Typical Applications

Roof Edges

Ice prevention for suitable roof-edge drainage installations.

Gutters and Downpipes

Helps reduce ice blockages and maintain drainage routes during cold weather.

Commercial Buildings

Snow and ice management for suitable commercial roof installations.

Hotels and Resorts

De-icing and roof drainage protection for suitable resort buildings.

Tall Buildings

Icicle prevention around selected elevated roof and drainage areas.

Infrastructure Projects

Manufacturer-listed applications include appropriate bridges and airport infrastructure.

SOLCO IcSR(e)40 Technical Specifications

Specification IcSR(e)40
Manufacturer SOLCO Pyroelec
Product Series IcSR(e)
Supplier Product Code IcSR(e)40 2-CV
Heating Cable Type Self-Regulating
Nominal Heating Output 40W/m at 0°C (Ice and Water)
Maximum Maintain Temperature 80°C (Power On)
Maximum Continuous Exposure 100°C (Power Off)
Approximate Cable Dimensions 13.4mm x 5.4mm
Bus Wire ASTM B355 Class 2 Nickel-Plated Copper, 16 AWG
Manufacturer Jacket Options P – UV-Resistant Polyolefin; F – Fluoropolymer
Primary Applications Roof and Gutter De-Icing, Snow Melting and Icicle Prevention

Specifications are based on SOLCO's published IcSR(e) technical information. Confirm the supplied jacket, operating voltage and circuit requirements for the 2-CV configuration before installation.

Weather-Resistant Cable Construction

SOLCO offers its IcSR heating cable range with UV-resistant polyolefin and fluoropolymer outer jacket options.

These materials are intended for different outdoor and environmental exposure conditions. The exact outer jacket supplied with the 2-CV configuration should be confirmed against the supplier specification.

Installation and System Requirements

SOLCO IcSR(e)40 should be specified as part of a correctly designed outdoor de-icing system.

Installation Considerations
  • Determine the appropriate cable route through roof edges, gutters and downpipe systems.
  • Select suitable temperature or moisture sensing controls for the installation.
  • Use manufacturer-compatible fixing clips, supports, connection kits and end seals.
  • Confirm the supplied cable jacket is suitable for the operating environment.
  • Ensure external connections and electrical enclosures are appropriately weather protected.
  • Verify maximum circuit lengths, breaker ratings and start-up conditions against SOLCO's technical documentation.
  • Follow manufacturer guidance for routing, termination, testing and commissioning.

Installation Note: Electrical installation must be completed by suitably qualified personnel using appropriate controls and protective devices.

Complete Your De-Icing Installation

Insulation & More supplies a range of trace heating products and associated controls for commercial installations.

INSULATION & MORE | TRADE SUPPLY

Need Roof and Gutter De-Icing for a Commercial Project?

Whether you require an individual cable length or heating cable for a larger roof drainage installation, our team can assist with product selection and project enquiries.

We supply trace heating cables, controllers and associated products for M&E contractors, electrical installers and commercial buyers.

✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options
View product