Free shipping for orders over £250! (Exc. VAT)

First Time Customer Discount

Get 5% off your first order! T&C

FIRSTFIVE

Trace Heating Cables Explained: Explore Our Complete Range for Every Application

Trace Heating Cables Explained: Explore Our Complete Range for Every Application

Jonathan Hill

From protecting exposed water pipes against freezing to maintaining temperatures in industrial process systems, selecting the correct trace heating cable is essential for reliable performance.

At Insulation & More, we have expanded our trace heating range with new products from SOLCO Pyroelec, alongside our existing cable solutions. Our collection now covers domestic, commercial and industrial applications, including specialist options for sprinkler systems, hot water maintenance and roof de-icing.

This guide introduces our complete range of 14 cables, explains their main applications and helps installers, contractors and maintenance teams identify suitable products for their projects.

One Range. Multiple Applications.

Explore self-regulating and constant wattage cables for frost protection, sprinkler pipework, hot water systems, roof and gutter de-icing and industrial process heating.

Find the Right Cable for Your Application

Not every trace heating cable is designed for the same operating conditions. Browse by application to quickly identify the most relevant products.

Self-Regulating vs Constant Wattage Trace Heating

Understanding the difference is a useful starting point when specifying an electric trace heating system.

SELF-REGULATING

Adaptive Heat Output

Self-regulating heating cable adjusts its heat output as the surrounding temperature changes. Colder sections produce more heat, while warmer sections reduce their output.

This technology is widely used for frost protection, pipe temperature maintenance, sprinkler systems and specialist industrial applications.

Suitable designs can be cut to length and may allow overlapping, subject to the manufacturer's instructions.

CONSTANT WATTAGE

Fixed Heat Output

Constant wattage heating cable delivers a defined electrical heat output per metre rather than automatically reducing its output as the surrounding temperature rises.

It is suitable for applications requiring predictable heating performance, provided the system is correctly designed and controlled.

Temperature regulation, correct cable spacing and compliance with permitted circuit and cutting lengths are particularly important.

Important: Self-regulating does not mean that a heating cable replaces a thermostat, suitable circuit protection or thermal insulation. The complete installation must be designed for its operating conditions.

APPLICATION 01

Trace Heating Cables for Pipe Frost Protection

Protecting water pipes and exposed building services against freezing is one of the most common applications for electric trace heating.

Our range includes general-purpose self-regulating cables, compact frost protection products and higher-output options for installations requiring additional heating performance. Typical applications include external pipe runs, unheated service areas and vulnerable water supplies.

SOLCO HSR self-regulating frost protection heating cable
SOLCO | SELF-REGULATING

HSR Heating Cable

A versatile range for water pipe frost protection and temperature maintenance in commercial and building-services installations.

10–30W/m range 65°C max. maintain
View HSR Cable
SOLCO MSR self-regulating trace heating cable
SOLCO | MEDIUM TEMPERATURE

MSR Self-Regulating Cable

For frost protection and medium-temperature maintenance, including suitable commercial pipework, plant rooms and service installations.

20–40W/m product range 80°C max. maintain
View MSR Cable
Insulation and More 10W per metre micro self-regulating cable
INSULATION & MORE

10W/m Micro Heating Cable

A compact self-regulating heating solution for smaller-scale frost protection applications and suitable pipe installations.

10W/m Compact cable
View Micro Cable
Constant wattage parallel electric trace heating cable
CONSTANT WATTAGE

Parallel Constant Wattage Cable

A fixed-output heating option for appropriately designed installations requiring controlled and consistent heat delivery.

Fixed output Temperature control
View Constant Wattage

APPLICATION 02

Fire Sprinkler Pipework Trace Heating

Specialist cable options for frost protection of suitable fire sprinkler installations.

Sprinkler pipework located in unheated areas can be vulnerable to freezing. Trace heating may be required as part of a properly designed frost protection system, incorporating suitable insulation, controls, monitoring and electrical protection.

BlazeTrace SSR102-CP fire sprinkler self-regulating cable
BLAZETRACE | SPRINKLER

BlazeTrace SSR102-CP

A 230V self-regulating heating cable for suitable fire sprinkler pipework, designed to provide frost protection where required.

10W/m at 10°C 230V
View BlazeTrace
SOLCO IPSR132-CP compact trace heating cable
SOLCO | COMPACT PIPEWORK

IPSR132-CP Heating Cable

A compact self-regulating cable designed for small-bore pipework, suitable sprinkler installations and commercial building services.

13W/m at 10°C 230V 50°C max. maintain
View IPSR Cable

Sprinkler systems must be assessed against the applicable BS EN 12845 requirements, project specifications and relevant fire protection guidance. Cable suitability alone does not establish system compliance.

APPLICATION 03

Hot Water Temperature Maintenance Cables

Specialist trace heating solutions designed to maintain hot water temperatures throughout suitable distribution pipework.

Unlike standard frost protection cables, hot water maintenance products are designed to help maintain specified operating temperatures. They can be considered as part of an appropriately designed hot water distribution system.

SOLCO HWS-R hot water maintenance trace heating cable
SOLCO | HOT WATER

HWS-R Heating Cable

Self-regulating trace heating designed for hot water temperature maintenance in suitable distribution systems.

50–60°C maintenance 9W/m at 55°C
View HWS-R
SOLCO hot water maintenance cable close-up showing cable construction
SOLCO | HOT WATER

HWS-P Heating Cable

Designed for hot water temperature maintenance with a wider stated operating range and a periodic disinfection capability within a suitable system design.

40–70°C maintenance 9.5W/m at 70°C
View HWS-P

Hot water temperature maintenance must be designed in accordance with relevant water hygiene and safety requirements. Cable selection does not replace a Legionella risk assessment.

APPLICATION 04

Roof, Gutter and Snow Melting Heating Cables

Trace heating is not limited to pipework. Specialist products can also help protect roofs, gutters, drainage systems and suitable surfaces from ice accumulation.

These applications can require different cable outputs, jackets and installation methods from standard pipe frost protection. Our range includes dedicated roof de-icing and embedded snow melting cable options.

SOLCO IcSR roof and gutter de-icing heating cable
SOLCO | ROOF DE-ICING

IcSR(e)40 2-CV Cable

A self-regulating heating cable developed for roof, gutter and downpipe de-icing applications where exposure to winter conditions is expected.

40W/m at 0°C in ice/water Roof and gutter use
View IcSR Cable
SOLCO SmSR1002-CX snow melting trace heating cable
SOLCO | SNOW MELTING

SmSR1002-CX Heating Cable

A specialist self-regulating cable designed for suitable concrete-embedded snow melting and de-icing systems.

100W/m Concrete installation
View SmSR Cable
SOLCO VSR high-output self-regulating heating cable
SOLCO | MULTI-APPLICATION

VSR Heating Cable

A versatile higher-output cable range suitable for specified frost protection, surface heating, snow melting and temperature maintenance applications.

16–50W/m range 110°C max. maintain
View VSR Cable

APPLICATION 05

Industrial Trace Heating for Process Applications

Specialist self-regulating heating cables for industrial temperature maintenance, freeze protection and higher-temperature duties.

Industrial installations often require greater attention to operating temperatures, chemical exposure, insulation specifications and system controls. The SOLCO FBL, FBH and FBX ranges provide different temperature capabilities for process applications.

SOLCO FBL industrial self-regulating trace heating cable
SOLCO | INDUSTRIAL

FBL Industrial Heating Cable

Designed for lower-temperature industrial process heating, freeze protection and temperature maintenance in suitable systems.

10–30W/m range 65°C max. maintain
View FBL Cable
SOLCO FBH medium to high temperature industrial heating cable
SOLCO | HIGHER TEMPERATURE

FBH Industrial Heating Cable

Suitable for specified medium-to-high temperature industrial process lines and equipment requiring temperature maintenance.

15–60W/m range 110°C max. maintain
View FBH Cable
SOLCO FBX high temperature industrial trace heating cable
SOLCO | HIGH TEMPERATURE

FBX Industrial Heating Cable

A higher-temperature cable range for demanding industrial applications, including suitable steam-purged pipework and process equipment.

15–60W/m range 150°C max. maintain
View FBX Cable

Industrial cable temperature ratings, jacket compatibility, hazardous-area suitability and circuit limits must be verified against the technical documentation for the exact product variant.

How to Choose the Right Trace Heating Cable

A few key project details will help determine which type of cable is most appropriate.

01

Identify the Application

Is the system protecting water pipes, maintaining hot water, heating a process line or preventing ice formation?

02

Establish the Temperatures

Check the required maintenance temperature, minimum ambient conditions and maximum temperatures the cable may experience.

03

Calculate the System

Consider pipe dimensions, insulation, heat loss, power supply, circuit length, electrical protection and control requirements.

04

Complete the Installation

Select suitable connection kits, fixing materials, controllers, insulation and weatherproof protection where required.

Need assistance? Our Pipework Product Finder can help narrow down product options for suitable frost protection applications. For more complex projects, contact our team with your installation requirements.

Complete Your Trace Heating Installation

Heating cable is only one part of a complete frost protection or temperature maintenance system. We also supply supporting components and insulation.

Controllers & Thermostats

Temperature regulation and monitoring products for suitable trace heating systems.

Explore Controllers →

Fixings & Accessories

Installation materials, connection components and termination accessories.

Explore Accessories →

Pipe Insulation

Suitable thermal insulation helps limit heat loss and supports effective trace heating operation.

Explore Pipe Insulation →

Need Trace Heating for Your Next Project?

Whether you require cable for a single pipe run or materials for a larger commercial installation, Insulation & More can help you source trace heating cables, controls, accessories and insulation.

Trade and project enquiries welcome | UK delivery available | Free standard delivery on eligible orders over £250 excluding VAT

FAQs

Frequently Asked Questions

1. What is a self-regulating trace heating cable?

A self-regulating trace heating cable automatically adjusts its heat output in response to changes in the surrounding temperature. It is commonly used for pipe frost protection, temperature maintenance and specialist commercial or industrial applications. Suitable controls and electrical protection may still be required.

2. What is the difference between self-regulating and constant wattage heating cable?

Self-regulating cables adjust their heat output as temperatures change, whereas constant wattage cables provide a fixed output per metre. Self-regulating cables are widely used for frost protection, while constant wattage systems require carefully designed temperature control and installation.

3. Which trace heating cable is suitable for fire sprinkler systems?

Our range includes BlazeTrace SSR102-CP and SOLCO IPSR132-CP self-regulating cables for suitable sprinkler pipework applications. The complete system must be designed in accordance with applicable fire protection standards, including BS EN 12845 where relevant.

4. Can trace heating cable be cut to length?

Many self-regulating heating cables can be cut to the required length on-site, subject to the manufacturer's instructions and maximum circuit lengths. Constant wattage cables may have specific cutting intervals. All cables require suitable connection and termination accessories.

5. Do I need pipe insulation with trace heating cable?

Yes, suitable thermal insulation is normally essential for pipe frost protection and temperature maintenance systems. Insulation reduces heat loss and helps the heating cable maintain the required temperature efficiently.

6. Can trace heating cables be used on roofs and gutters?

Yes. Specialist products such as the SOLCO IcSR(e)40 2-CV are designed for roof, gutter and downpipe de-icing. Other products, including the SmSR range, are intended for suitable embedded snow melting applications.

7. Does Insulation & More supply complete trace heating systems?

Insulation & More supplies a comprehensive range of trace heating cables, controllers, thermostats, fixing accessories, connection components and pipe insulation. These products can be selected together to support domestic, commercial and industrial installations, subject to compatibility and project requirements.