From protecting exposed water pipes against freezing to maintaining temperatures in industrial process systems, selecting the correct trace heating cable is essential for reliable performance.
At Insulation & More, we have expanded our trace heating range with new products from SOLCO Pyroelec, alongside our existing cable solutions. Our collection now covers domestic, commercial and industrial applications, including specialist options for sprinkler systems, hot water maintenance and roof de-icing.
This guide introduces our complete range of 14 cables, explains their main applications and helps installers, contractors and maintenance teams identify suitable products for their projects.
One Range. Multiple Applications.
Explore self-regulating and constant wattage cables for frost protection, sprinkler pipework, hot water systems, roof and gutter de-icing and industrial process heating.
Find the Right Cable for Your Application
Not every trace heating cable is designed for the same operating conditions. Browse by application to quickly identify the most relevant products.
Self-Regulating vs Constant Wattage Trace Heating
Understanding the difference is a useful starting point when specifying an electric trace heating system.
Adaptive Heat Output
Self-regulating heating cable adjusts its heat output as the surrounding temperature changes. Colder sections produce more heat, while warmer sections reduce their output.
This technology is widely used for frost protection, pipe temperature maintenance, sprinkler systems and specialist industrial applications.
Suitable designs can be cut to length and may allow overlapping, subject to the manufacturer's instructions.
Fixed Heat Output
Constant wattage heating cable delivers a defined electrical heat output per metre rather than automatically reducing its output as the surrounding temperature rises.
It is suitable for applications requiring predictable heating performance, provided the system is correctly designed and controlled.
Temperature regulation, correct cable spacing and compliance with permitted circuit and cutting lengths are particularly important.
Important: Self-regulating does not mean that a heating cable replaces a thermostat, suitable circuit protection or thermal insulation. The complete installation must be designed for its operating conditions.
APPLICATION 01
Trace Heating Cables for Pipe Frost Protection
Protecting water pipes and exposed building services against freezing is one of the most common applications for electric trace heating.
Our range includes general-purpose self-regulating cables, compact frost protection products and higher-output options for installations requiring additional heating performance. Typical applications include external pipe runs, unheated service areas and vulnerable water supplies.

HSR Heating Cable
A versatile range for water pipe frost protection and temperature maintenance in commercial and building-services installations.

MSR Self-Regulating Cable
For frost protection and medium-temperature maintenance, including suitable commercial pipework, plant rooms and service installations.

10W/m Micro Heating Cable
A compact self-regulating heating solution for smaller-scale frost protection applications and suitable pipe installations.

Parallel Constant Wattage Cable
A fixed-output heating option for appropriately designed installations requiring controlled and consistent heat delivery.
APPLICATION 02
Fire Sprinkler Pipework Trace Heating
Specialist cable options for frost protection of suitable fire sprinkler installations.
Sprinkler pipework located in unheated areas can be vulnerable to freezing. Trace heating may be required as part of a properly designed frost protection system, incorporating suitable insulation, controls, monitoring and electrical protection.

BlazeTrace SSR102-CP
A 230V self-regulating heating cable for suitable fire sprinkler pipework, designed to provide frost protection where required.

IPSR132-CP Heating Cable
A compact self-regulating cable designed for small-bore pipework, suitable sprinkler installations and commercial building services.
Sprinkler systems must be assessed against the applicable BS EN 12845 requirements, project specifications and relevant fire protection guidance. Cable suitability alone does not establish system compliance.
APPLICATION 03
Hot Water Temperature Maintenance Cables
Specialist trace heating solutions designed to maintain hot water temperatures throughout suitable distribution pipework.
Unlike standard frost protection cables, hot water maintenance products are designed to help maintain specified operating temperatures. They can be considered as part of an appropriately designed hot water distribution system.

HWS-R Heating Cable
Self-regulating trace heating designed for hot water temperature maintenance in suitable distribution systems.

HWS-P Heating Cable
Designed for hot water temperature maintenance with a wider stated operating range and a periodic disinfection capability within a suitable system design.
Hot water temperature maintenance must be designed in accordance with relevant water hygiene and safety requirements. Cable selection does not replace a Legionella risk assessment.
APPLICATION 04
Roof, Gutter and Snow Melting Heating Cables
Trace heating is not limited to pipework. Specialist products can also help protect roofs, gutters, drainage systems and suitable surfaces from ice accumulation.
These applications can require different cable outputs, jackets and installation methods from standard pipe frost protection. Our range includes dedicated roof de-icing and embedded snow melting cable options.

IcSR(e)40 2-CV Cable
A self-regulating heating cable developed for roof, gutter and downpipe de-icing applications where exposure to winter conditions is expected.

SmSR1002-CX Heating Cable
A specialist self-regulating cable designed for suitable concrete-embedded snow melting and de-icing systems.

VSR Heating Cable
A versatile higher-output cable range suitable for specified frost protection, surface heating, snow melting and temperature maintenance applications.
APPLICATION 05
Industrial Trace Heating for Process Applications
Specialist self-regulating heating cables for industrial temperature maintenance, freeze protection and higher-temperature duties.
Industrial installations often require greater attention to operating temperatures, chemical exposure, insulation specifications and system controls. The SOLCO FBL, FBH and FBX ranges provide different temperature capabilities for process applications.

FBL Industrial Heating Cable
Designed for lower-temperature industrial process heating, freeze protection and temperature maintenance in suitable systems.

FBH Industrial Heating Cable
Suitable for specified medium-to-high temperature industrial process lines and equipment requiring temperature maintenance.

FBX Industrial Heating Cable
A higher-temperature cable range for demanding industrial applications, including suitable steam-purged pipework and process equipment.
Industrial cable temperature ratings, jacket compatibility, hazardous-area suitability and circuit limits must be verified against the technical documentation for the exact product variant.
How to Choose the Right Trace Heating Cable
A few key project details will help determine which type of cable is most appropriate.
Identify the Application
Is the system protecting water pipes, maintaining hot water, heating a process line or preventing ice formation?
Establish the Temperatures
Check the required maintenance temperature, minimum ambient conditions and maximum temperatures the cable may experience.
Calculate the System
Consider pipe dimensions, insulation, heat loss, power supply, circuit length, electrical protection and control requirements.
Complete the Installation
Select suitable connection kits, fixing materials, controllers, insulation and weatherproof protection where required.
Need assistance? Our Pipework Product Finder can help narrow down product options for suitable frost protection applications. For more complex projects, contact our team with your installation requirements.
Complete Your Trace Heating Installation
Heating cable is only one part of a complete frost protection or temperature maintenance system. We also supply supporting components and insulation.
Controllers & Thermostats
Temperature regulation and monitoring products for suitable trace heating systems.
Explore Controllers →Fixings & Accessories
Installation materials, connection components and termination accessories.
Explore Accessories →Pipe Insulation
Suitable thermal insulation helps limit heat loss and supports effective trace heating operation.
Explore Pipe Insulation →Need Trace Heating for Your Next Project?
Whether you require cable for a single pipe run or materials for a larger commercial installation, Insulation & More can help you source trace heating cables, controls, accessories and insulation.
Trade and project enquiries welcome | UK delivery available | Free standard delivery on eligible orders over £250 excluding VAT
Technical information: The product descriptions and temperature/output figures in this article are general guidance based on the listed products and published manufacturer information. Actual suitability depends on the exact cable model, voltage, outer jacket, operating conditions and installation design. Always review the latest manufacturer's technical documentation. Electrical trace heating systems must be designed, installed, tested and commissioned by competent personnel in accordance with applicable regulations and project requirements.