November 23, 2026Industrial trace heating plays an important role in maintaining process temperatures, protecting pipelines against freezing and supporting reliable operation in demanding industrial environments.
Unlike general building-services frost protection, industrial installations may involve elevated temperatures, chemical exposure, hazardous areas and complex operating cycles. These conditions make cable selection particularly important.
At Insulation & More, our expanded trace heating cable collection includes three specialist SOLCO Pyroelec industrial self-regulating cable families: FBL, FBH and FBX.
This guide explains the technical differences between these cable families, compares their available variants and highlights the applications and installation considerations engineers should assess before specifying an industrial trace heating system.
Three Cable Families. Different Temperature Capabilities.
From lower-temperature frost protection to high-temperature process maintenance, compare the SOLCO industrial range and identify the appropriate starting point for your installation.
How Does Industrial Self-Regulating Trace Heating Work?
Understanding the heating principle is essential when comparing industrial cable outputs and operating temperatures.
Self-regulating heating cables incorporate a temperature-responsive conductive core between two parallel electrical conductors. As the cable temperature changes, the electrical resistance of the core changes, altering the heat produced along its length.
Colder sections produce greater heating output, while warmer sections reduce their output. This allows the cable to respond locally to temperature differences along a pipe or piece of equipment.
SOLCO describes cut-to-length flexibility and overlap tolerance for its FBL, FBH and FBX families, subject to the manufacturer's installation requirements.
Important: Self-regulating performance does not eliminate the need for suitable temperature controls, electrical protection or engineering calculations. Cable output also changes with temperature, so nominal W/m ratings should not be treated as constant operating output.
Understanding the Three SOLCO Industrial Cable Families
Each range serves a different temperature and process requirement.
LOWER TEMPERATURE
SOLCO FBL
65°CMaximum powered maintenance temperature.
Developed for freeze protection and lower-temperature industrial process maintenance.
- Water pipeline frost protection
- Process line temperature maintenance
- Petrochemical and gas plant applications
MEDIUM-HIGH TEMPERATURE
SOLCO FBH
110°CMaximum powered maintenance temperature.
Designed for demanding process pipework requiring higher operating temperatures and heating outputs.
- Fuel and chemical pipelines
- Industrial process heating
- Petrochemical and gas facilities
HIGH TEMPERATURE
SOLCO FBX
150°CMaximum powered maintenance temperature.
Developed for higher-temperature process maintenance and installations that may experience steam purging.
- Steam-purged pipework
- High-temperature process lines
- Industrial hopper heating
Industrial Trace Heating Cable Specifications Compared
Compare the principal technical specifications of the three SOLCO cable families available from Insulation & More.
| Specification | FBL | FBH | FBX |
|---|---|---|---|
| Typical duty | Low temperature | Medium/high temperature | High temperature |
| Rated outputs | 10, 16, 24, 30W/m | 15, 30, 45, 60W/m | 15, 30, 45, 60W/m |
| Max. maintain (power on) | 65°C | 110°C | 150°C |
| Max. withstand (power off) | 85°C | 135°C | 200°C |
| Min. installation temperature | -60°C | -55°C | -60°C |
| Temperature classification | T6 | T4 | T3 / T2 |
| Listed supply variants | 200–277V AC | 200–277V AC | 200–277V AC |
| Stocked jacket option | CF fluoropolymer | CT fluoropolymer | CT fluoropolymer |
| Typical applications | Frost protection and process maintenance | Fuel, chemical and process pipelines | Steam-purged and high-temperature processes |
| Product details | View FBL | View FBH | View FBX |
Outputs are manufacturer nominal ratings at 10°C. Voltage and jacket entries reflect the variants currently listed by Insulation & More, not every configuration manufactured by SOLCO. Maximum temperatures are not interchangeable with normal operating setpoints.
Why the two temperature ratings matter: A cable's maximum powered maintenance temperature describes the manufacturer's operating limit while energised. The maximum unpowered withstand temperature describes its permitted exposure under specified conditions while switched off. Both must be considered when the process itself can heat the pipework.
INDUSTRIAL PRODUCT RANGE
Explore SOLCO Industrial Heating Cables
Three self-regulating cable families with different output and temperature capabilities for industrial installations.
SOLCO FBL
An industrial cable for frost protection and lower-temperature process maintenance, including suitable water pipelines and petrochemical plant installations.
SOLCO FBH
Designed for industrial process heating where higher output and maintenance temperatures are required, including suitable fuel and chemical pipelines.
SOLCO FBX
Designed for high-temperature process heating, including suitable steam-purged pipelines and demanding industrial equipment.
Comparing the Available Cable Outputs
Each SOLCO industrial family offers different nominal power outputs to suit calculated heating requirements.
Increasing the nominal output does not automatically make a cable more appropriate. The required W/m must be established by comparing calculated heat loss with the manufacturer's output graph at the intended maintenance temperature.
FBL Variants
FBL102-CF – 10W/m
FBL162-CF – 16W/m
FBL242-CF – 24W/m
FBL302-CF – 30W/m
Suitable for correctly designed lower-temperature maintenance and frost protection systems.
Compare FBL Variants →FBH Variants
FBH152-CT – 15W/m
FBH302-CT – 30W/m
FBH452-CT – 45W/m
FBH602-CT – 60W/m
A range of outputs for medium-to-high-temperature industrial process duties.
Compare FBH Variants →FBX Variants
FBX152-CT – 15W/m
FBX302-CT – 30W/m
FBX452-CT – 45W/m
FBX602-CT – 60W/m
High-temperature cable options for demanding industrial process heating.
Compare FBX Variants →Output example: A pipe calculated to lose 22W/m at its required maintenance temperature cannot automatically be matched with any cable labelled 24W/m or 30W/m. The cable's actual output at that pipe temperature must be checked, together with allowances for fittings, valves, supports and operating conditions.
FBL vs FBH vs FBX: The Main Engineering Differences
Temperature performance, operating conditions and cable construction are the main considerations when comparing these ranges.
1. Maximum Operating Temperature
The FBL family is rated for powered maintenance up to 65°C. The FBH range increases the limit to 110°C, while FBX extends it to 150°C.
These values describe the manufacturer's maximum permitted powered maintenance temperatures, not the temperature each cable will automatically achieve in an installation.
2. Maximum Unpowered Exposure Temperature
Process pipework may reach temperatures above the required heating setpoint because of the process itself. The cable must withstand this exposure even when electrical heating is switched off.
FBL has an 85°C withstand rating, FBH is rated to 135°C, and FBX is rated to 200°C under the manufacturer's stated conditions.
3. Heat Output Options
The FBL family offers nominal outputs from 10 to 30W/m. Both FBH and FBX offer 15, 30, 45 and 60W/m variants.
Because these cables self-regulate, the published wattage is specified at a reference temperature of 10°C. Output curves and heat-loss calculations are needed to determine whether a particular variant meets the design duty.
4. Outer Jacket and Chemical Exposure
All three industrial products currently listed by Insulation & More use fluoropolymer jacket variants: CF for FBL, and CT for FBH and FBX.
SOLCO identifies fluoropolymer jacket options for exposure to organic chemicals and corrosive environments. However, specific compatibility with the substances present on a site must be confirmed before installation.
5. Temperature Classification
Industrial trace heating may be installed in environments where maximum surface temperature limitations are important. Published cable temperature classifications include T6 for FBL, T4 for FBH, and T3 or T2 depending on the FBX variant.
A cable's temperature classification is not, by itself, proof that a complete heating system is suitable for a particular hazardous area. The applicable certification, area classification, accessories and installation design must all be verified.
Industrial Trace Heating Applications & Cable Selection
These practical examples explain where each cable family may be considered and what engineers need to verify.
Industrial Water Pipeline Frost Protection
Water pipelines in industrial plants may be exposed to freezing temperatures, particularly along outdoor pipe racks, unheated service areas and exposed distribution routes.
SOLCO FBL is a potential starting point for lower-temperature frost protection where its operating limits and calculated heating output are appropriate.
Fuel Transfer and Chemical Process Lines
Some process fluids require temperature maintenance to retain suitable flow characteristics or avoid solidification. Required temperatures differ significantly depending on the fluid and process.
SOLCO FBL may be considered for lower-temperature requirements, while SOLCO FBH provides higher-temperature capabilities. The chemical environment and required cable jacket must be evaluated separately.
Petrochemical and Gas Plant Temperature Maintenance
Process pipework in petrochemical and gas facilities may require trace heating to maintain operational temperatures under varying environmental conditions.
Depending on the required temperature, suitable cable families may include FBL, FBH or FBX. Hazardous-area suitability and electrical system requirements must be checked for the specific site.
Steam-Purged Industrial Pipelines
Steam purging can expose pipework to temperatures significantly higher than its normal trace heating maintenance setpoint.
SOLCO FBX has a published maximum unpowered withstand rating of 200°C and is manufacturer-listed for suitable steam-purged pipelines.
The full steam-purge temperature profile, duration, equipment ratings and control strategy must be confirmed before specification.
Industrial Hoppers and Heat-Up Processes
Industrial process equipment may require supplementary heating to maintain material flow or support heat-up operations.
SOLCO lists hopper heating and medium-to-heavy-duty heat-up processes among the applications for FBX.
These applications require careful evaluation of heat transfer, mounting arrangements, equipment geometry and operating conditions.
Choosing the Correct Outer Jacket
The heating cable's outer jacket forms part of its protection against the installation environment.
Industrial heating cables can be exposed to moisture, process chemicals, cleaning agents and corrosive industrial environments. Selecting a jacket solely by cable temperature rating is insufficient.
| Jacket | Material | Manufacturer-listed use | Applicable cable family |
|---|---|---|---|
| CP | Flame-retardant polyolefin | Aqueous inorganic chemical exposure | FBL family option |
| CF | Fluoropolymer | Organic chemical or corrosive exposure | FBL |
| CX | Flame-retardant XLEVA | Aqueous inorganic chemical exposure | FBH family option |
| CT | Fluoropolymer | Organic chemical or corrosive exposure | FBH, FBX |
CP and CX are manufacturer-listed options, but the linked Insulation & More products currently list CF and CT variants. Availability and compatibility should be confirmed before ordering.
Industrial Trace Heating in Hazardous Areas
Some industrial installations require additional certification and electrical protection because of potentially explosive atmospheres.
SOLCO lists hazardous-area applications for its industrial cable families. However, individual cable ratings do not establish that an entire trace heating installation is compliant.
Before specifying a system for a classified area, the designer must confirm the area classification, applicable equipment certification, temperature class, approved termination accessories and installation requirements.
Industrial Trace Heating Selection Checklist
These six considerations should be addressed before selecting a heating cable for process pipework.
Required Process Temperature
Establish the minimum required maintenance temperature and maximum process temperature, including shutdown and cleaning cycles.
Pipe Dimensions & Heat Loss
Consider pipe diameter, material, length, supports, fittings, insulation properties and ambient conditions.
Heat Output at Operating Temperature
Compare calculated heat loss with the manufacturer's cable output graph rather than relying on nominal W/m alone.
Environmental Compatibility
Confirm chemical exposure, moisture, weathering, mechanical protection and the appropriate jacket material.
Electrical Design & Certification
Check supply voltage, circuit length, start-up current, protection, controls and any hazardous-area requirements.
Insulation & Installation Accessories
Select compatible thermal insulation, connection kits, end terminations, junction boxes and protective cladding.
Complete Your Industrial Trace Heating System
The heating cable must be specified alongside suitable controls, connections and insulation.
Specifying Industrial Trace Heating?
Compare our SOLCO industrial cable range and source compatible controls, installation accessories, thermal insulation and cladding for your project.
For technical and trade enquiries, provide the required temperature, process conditions, pipe dimensions, cable length and relevant site requirements.
Technical information: Specifications are based on published SOLCO Pyroelec product information and the listed Insulation & More variants. Product specifications, certifications and availability may change. All technical ratings must be confirmed against the latest manufacturer's documentation. Applications shown are indicative, not complete system designs. Industrial and hazardous-area installations must be designed, installed and commissioned by competent personnel in accordance with applicable requirements.