{"product_id":"smsr1002-cx-self-regulating-heating-cable","title":"SmSR1002-CX Self-Regulating Snow Melting Cable – 100W\/m","description":"\n\u003cdiv style=\"display:flex;align-items:center;gap:11px;background:#DCEBFC;border:1px solid #C1D9F4;border-radius:6px;padding:11px 13px;margin:12px 0;font-family:Arial,Helvetica,sans-serif;color:#142D46;\"\u003e\n  \u003csvg width=\"19\" height=\"19\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#142D46\" stroke-width=\"1.7\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"flex-shrink:0;\" aria-hidden=\"true\"\u003e\n    \u003ccircle cx=\"12\" cy=\"12\" r=\"9\"\u003e\u003c\/circle\u003e\n    \u003cpath d=\"M12 7v5l3 2\"\u003e\u003c\/path\u003e\n  \u003c\/svg\u003e\n  \u003cdiv style=\"min-width:0;\"\u003e\n    \u003cdiv style=\"font-size:14px;line-height:1.45;font-weight:400;color:#142D46;\"\u003e\n      Estimated lead time: \u003cstrong style=\"font-weight:700;\"\u003e12 weeks\u003c\/strong\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"font-size:12px;line-height:1.5;color:#34465A;margin-top:2px;\"\u003e\n      Need it sooner?\n      \u003ca href=\"https:\/\/insulation-more.co.uk\/pages\/contact\" style=\"color:#176FD6;font-weight:600;text-decoration:underline;\"\u003eContact our team\u003c\/a\u003e\n      before ordering.\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\n\u003cstyle\u003e\n.im-smsr{\n --blue:#2D89F7;\n --red:#EC2D2C;\n --navy:#142D46;\n --text:#34465A;\n --muted:#617287;\n --pale:#F3F7FC;\n --border:#DDE7F1;\n font:14px\/1.65 Arial,Helvetica,sans-serif;\n color:var(--text);\n max-width:100%;\n}\n.im-smsr *{box-sizing:border-box}\n.im-smsr h2,.im-smsr h3{\n color:var(--navy);\n font-weight:700;\n line-height:1.35;\n margin:0 0 12px;\n}\n.im-smsr h2{font-size:22px}\n.im-smsr h3{font-size:18px}\n.im-smsr p{margin:0 0 12px}\n.im-smsr section{margin-bottom:25px}\n.im-smsr .intro{\n background:#F1F7FF;\n border:1px solid #D8E8FC;\n border-left:4px solid var(--blue);\n padding:20px;\n border-radius:7px;\n}\n.im-smsr .eyebrow{\n color:#1672DB;\n font-size:11px;\n font-weight:700;\n letter-spacing:1px;\n text-transform:uppercase;\n margin-bottom:8px;\n}\n.im-smsr .heading{\n border-bottom:2px solid var(--blue);\n padding-bottom:9px;\n margin-bottom:14px;\n}\n.im-smsr .stats{\n display:grid;\n grid-template-columns:repeat(4,minmax(0,1fr));\n gap:9px;\n margin:0 0 25px;\n}\n.im-smsr .stat{\n text-align:center;\n background:var(--pale);\n border:1px solid var(--border);\n border-radius:7px;\n padding:14px 8px;\n}\n.im-smsr .stat strong{\n display:block;\n font-size:20px;\n color:var(--blue);\n line-height:1.3;\n}\n.im-smsr .stat span{\n display:block;\n font-size:11px;\n color:var(--muted);\n margin-top:5px;\n}\n.im-smsr .features{\n display:grid;\n grid-template-columns:repeat(2,minmax(0,1fr));\n gap:11px;\n}\n.im-smsr .feature{\n background:#fff;\n border:1px solid var(--border);\n border-radius:7px;\n padding:15px;\n}\n.im-smsr .feature strong{\n display:block;\n color:var(--navy);\n margin-bottom:6px;\n}\n.im-smsr .feature strong:before{\n content:\"✓\";\n color:var(--blue);\n margin-right:8px;\n}\n.im-smsr .feature p{\n font-size:13px;\n color:var(--muted);\n margin:0;\n}\n.im-smsr .applications{\n display:grid;\n grid-template-columns:repeat(3,minmax(0,1fr));\n gap:11px;\n}\n.im-smsr .application{\n background:var(--pale);\n border-top:3px solid var(--blue);\n border-radius:7px;\n padding:16px;\n}\n.im-smsr .application strong{\n display:block;\n color:var(--navy);\n margin-bottom:6px;\n}\n.im-smsr .application p{\n font-size:13px;\n margin:0;\n}\n.im-smsr .table-wrap{overflow-x:auto}\n.im-smsr table{\n width:100%;\n border-collapse:collapse;\n font-size:13px;\n}\n.im-smsr th{\n padding:11px 13px;\n text-align:left;\n background:var(--navy);\n color:#fff;\n}\n.im-smsr td{\n padding:10px 13px;\n border-bottom:1px solid var(--border);\n vertical-align:top;\n}\n.im-smsr tr:nth-child(even) td{\n background:var(--pale);\n}\n.im-smsr td:first-child{\n font-weight:600;\n color:var(--navy);\n width:45%;\n}\n.im-smsr .info{\n padding:17px;\n background:#F1F7FF;\n border-left:3px solid var(--blue);\n border-radius:0 7px 7px 0;\n}\n.im-smsr .info p:last-child{margin:0}\n.im-smsr ul{\n padding-left:21px;\n margin:10px 0;\n}\n.im-smsr li{margin-bottom:6px}\n.im-smsr .related{\n display:grid;\n grid-template-columns:repeat(3,minmax(0,1fr));\n gap:11px;\n}\n.im-smsr .related-item{\n display:flex;\n flex-direction:column;\n justify-content:space-between;\n background:var(--pale);\n border:1px solid var(--border);\n border-radius:7px;\n padding:15px;\n}\n.im-smsr .related-item strong{\n display:block;\n color:var(--navy);\n}\n.im-smsr .related-item p{\n font-size:12px;\n color:var(--muted);\n margin:6px 0 13px;\n}\n.im-smsr .btn{\n display:inline-block;\n text-decoration:none!important;\n text-align:center;\n border-radius:5px;\n padding:11px 16px;\n font-size:13px;\n font-weight:700;\n line-height:1.4;\n}\n.im-smsr .btn-blue{\n background:var(--blue);\n color:#fff!important;\n}\n.im-smsr .btn-blue:hover{background:#176FD6}\n.im-smsr .btn-red{\n background:var(--red);\n color:#fff!important;\n}\n.im-smsr .btn-red:hover{background:#D51F1E}\n.im-smsr .btn-outline{\n background:transparent;\n color:#fff!important;\n border:1px solid #fff;\n}\n.im-smsr .btn-outline:hover{\n background:#fff;\n color:var(--navy)!important;\n}\n.im-smsr .related-item .btn{\n width:100%;\n padding:9px;\n font-size:12px;\n}\n.im-smsr .cta{\n background:linear-gradient(120deg,#142D46,#1B4875);\n color:#fff;\n padding:24px;\n border-radius:9px;\n}\n.im-smsr .cta h3{\n color:#fff;\n font-size:21px;\n}\n.im-smsr .cta p{color:#E1EBF6}\n.im-smsr .actions{\n display:flex;\n flex-wrap:wrap;\n gap:10px;\n margin-top:17px;\n}\n.im-smsr .fine{\n font-size:12px;\n color:var(--muted);\n}\n@media(max-width:700px){\n .im-smsr .stats{\n  grid-template-columns:repeat(2,minmax(0,1fr));\n }\n .im-smsr .applications,\n .im-smsr .related{\n  grid-template-columns:1fr;\n }\n}\n@media(max-width:480px){\n .im-smsr .features{grid-template-columns:1fr}\n .im-smsr h2{font-size:20px}\n .im-smsr .intro,.im-smsr .cta{padding:17px}\n .im-smsr .actions{flex-direction:column}\n .im-smsr .actions a{width:100%}\n}\n\u003c\/style\u003e\n\u003cdiv class=\"im-smsr\"\u003e\n\u003c!-- INTRODUCTION --\u003e\n\u003csection class=\"intro\"\u003e\n\u003ch2\u003eSOLCO SmSR1002-CX Self-Regulating Snow Melting Heating Cable – 100W\/m\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSOLCO SmSR1002-CX Self-Regulating Heating Cable\u003c\/strong\u003e is a high-output electric trace heating cable designed for \u003cstrong\u003esnow melting and anti-icing in concrete pavements, ramps and access roads\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSpecifically developed for direct installation within concrete, SmSR provides a robust heating solution for pedestrian and vehicle access areas exposed to freezing winter conditions.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eRated at \u003cstrong\u003e100W\/m at 0°C in ice-and-water conditions\u003c\/strong\u003e, the 230V cable automatically adjusts its heat output in response to surrounding temperature changes.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- QUICK SPECIFICATIONS --\u003e\n\u003cdiv class=\"stats\"\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e100W\/m\u003c\/strong\u003e \u003cspan\u003eAt 0°C in Ice and Water\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e230V\u003c\/strong\u003e \u003cspan\u003eAC Supply\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e80°C\u003c\/strong\u003e \u003cspan\u003eMax. Maintain Temperature\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e135°C\u003c\/strong\u003e \u003cspan\u003eMax. Exposure, Power Off\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- MAIN APPLICATION --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eSnow Melting and Anti-Icing for Concrete Surfaces\u003c\/h3\u003e\n\u003cp\u003eSnow and ice accumulation on access roads, pedestrian pavements and vehicle ramps can create hazardous surface conditions during winter weather.\u003c\/p\u003e\n\u003cp\u003eSOLCO SmSR is designed to provide distributed electric heating within concrete surfaces, helping reduce snow accumulation and ice formation when installed as part of a correctly designed de-icing system.\u003c\/p\u003e\n\u003cp\u003eIts high-output construction makes it particularly suitable for commercial and infrastructure projects requiring dependable surface heating.\u003c\/p\u003e\n\u003cdiv class=\"info\"\u003e\n\u003cstrong style=\"color: #142d46;\"\u003e Designed for Direct Installation in Concrete \u003c\/strong\u003e\n\u003cp style=\"margin-top: 8px;\"\u003eSmSR is specifically manufactured for direct burial in concrete, making it suitable for integrated heating systems within pavements, access roads and car park ramps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- HOW IT WORKS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eHow SOLCO SmSR Self-Regulating Heating Cable Works\u003c\/h3\u003e\n\u003cp\u003eSmSR incorporates a self-regulating heating element that changes its electrical resistance in response to temperature.\u003c\/p\u003e\n\u003cp\u003eWhen temperatures decrease, the cable increases its heat output. As the surrounding temperature rises, the heat output reduces automatically.\u003c\/p\u003e\n\u003cp\u003eIndividual sections of the cable respond to local temperature conditions, helping deliver variable heat output throughout the installation.\u003c\/p\u003e\n\u003cp\u003eThis technology is particularly useful for outdoor surface heating systems, where temperature conditions can vary across different areas of the same pavement or ramp.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- FEATURES --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cdiv class=\"features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e High-Output Snow Melting \u003c\/strong\u003e\n\u003cp\u003eProvides 100W\/m at 0°C in ice-and-water conditions for demanding pavement heating applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Concrete Installation \u003c\/strong\u003e\n\u003cp\u003eSpecifically designed for direct burial in concrete pavements, roads and ramps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Self-Regulating Technology \u003c\/strong\u003e\n\u003cp\u003eAutomatically adjusts heat output in response to local temperature changes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Overlap-Tolerant Design \u003c\/strong\u003e\n\u003cp\u003eManufacturer-designed to resist burning or overheating when overlapped under specified conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Cut-to-Length Flexibility \u003c\/strong\u003e\n\u003cp\u003eCan be cut to suit installation requirements, subject to maximum circuit lengths and correct termination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Robust Construction \u003c\/strong\u003e\n\u003cp\u003eManufactured for demanding installation conditions and high-temperature exposure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e XLEVA Outer Jacket \u003c\/strong\u003e\n\u003cp\u003eFeatures the manufacturer's specified XLEVA outer jacket construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e Soft Power Switching \u003c\/strong\u003e\n\u003cp\u003eManufacturer-designed power switching supports operating efficiency and cable service life.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eTypical Applications\u003c\/h3\u003e\n\u003cdiv class=\"applications\"\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eCar Park Ramps\u003c\/strong\u003e\n\u003cp\u003eAnti-icing systems for sloped vehicle entrances and commercial car park access areas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eConcrete Pavements\u003c\/strong\u003e\n\u003cp\u003eSnow melting for suitable pedestrian routes, walkways and paved areas.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eCommercial Entrances\u003c\/strong\u003e\n\u003cp\u003eSurface heating for entrances to offices, public buildings and commercial premises.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eAccess Roads\u003c\/strong\u003e\n\u003cp\u003eDe-icing installations for roads serving suitable commercial developments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eHoliday Resorts\u003c\/strong\u003e\n\u003cp\u003eSnow melting for entrance roads serving resorts and golf courses.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eInfrastructure Projects\u003c\/strong\u003e\n\u003cp\u003eManufacturer-listed applications include bridges and airport infrastructure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- OUTPUT INFORMATION --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eHeating Output and Performance\u003c\/h3\u003e\n\u003cp\u003eSOLCO SmSR1002-CX has two published heat output ratings depending on the surrounding ice and moisture conditions.\u003c\/p\u003e\n\u003cdiv class=\"table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTest Conditions\u003c\/th\u003e\n\u003cth\u003eRated Heat Output\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C – Ice and Water\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100W\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0°C – Ice\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120W\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"fine\" style=\"margin-top: 10px;\"\u003eThese ratings describe the same SmSR1002-CX cable under different conditions. They are not separate heating cable variants.\u003c\/p\u003e\n\u003cdiv class=\"info\"\u003e\n\u003cstrong style=\"color: #142d46;\"\u003e Selecting the Correct Heating Layout \u003c\/strong\u003e\n\u003cp style=\"margin-top: 8px;\"\u003eThe required cable spacing and total installed heating capacity depend on the surface construction, expected weather conditions, desired performance and calculated heat requirement.\u003c\/p\u003e\n\u003cp\u003eSOLCO describes typical system design outputs of approximately 300W\/m² or greater for snow melting and approximately 150W\/m² for de-icing applications. These are application guidance figures rather than universal installation requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eSOLCO SmSR1002-CX Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eSmSR1002-CX\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSOLCO Pyroelec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eSmSR1002-CX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eSelf-Regulating Heating Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003ePavement Snow Melting and Anti-Icing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output – Ice and Water\u003c\/td\u003e\n\u003ctd\u003e100W\/m at 0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output – Ice\u003c\/td\u003e\n\u003ctd\u003e120W\/m at 0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplied Voltage\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Class\u003c\/td\u003e\n\u003ctd\u003e200–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Maintain Temperature\u003c\/td\u003e\n\u003ctd\u003e80°C (Power On)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Exposure\u003c\/td\u003e\n\u003ctd\u003e135°C (Power Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Wire\u003c\/td\u003e\n\u003ctd\u003eASTM B355 Class 2 Nickel-Plated Copper, 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Dimensions\u003c\/td\u003e\n\u003ctd\u003e18.6 ± 0.2mm × 9.4 ± 0.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Jacket\u003c\/td\u003e\n\u003ctd\u003eXLEVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eDesigned for Direct Burial in Concrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"fine\" style=\"margin-top: 10px;\"\u003eTechnical values are based on SOLCO's published SmSR1002-CX specifications. Confirm circuit lengths, breaker ratings, cable spacing and installation requirements using the latest manufacturer guidance.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- INSTALLATION --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eInstallation and System Requirements\u003c\/h3\u003e\n\u003cp\u003eSOLCO SmSR1002-CX should be installed as part of a properly designed pavement snow melting or anti-icing system.\u003c\/p\u003e\n\u003cdiv class=\"info\"\u003e\n\u003cstrong style=\"color: #142d46;\"\u003e Installation Considerations \u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eDetermine the total surface area and required heating output per square metre.\u003c\/li\u003e\n\u003cli\u003eCalculate cable spacing and the required cable length for the installation.\u003c\/li\u003e\n\u003cli\u003ePlan the cable layout and installation depth according to the concrete surface construction.\u003c\/li\u003e\n\u003cli\u003eUse suitable temperature, snow and moisture sensing controls.\u003c\/li\u003e\n\u003cli\u003eSelect compatible connections, end seals and fixing accessories.\u003c\/li\u003e\n\u003cli\u003eVerify maximum circuit lengths and protective device ratings against SOLCO's technical data.\u003c\/li\u003e\n\u003cli\u003eProtect the heating cable against installation damage during concrete placement.\u003c\/li\u003e\n\u003cli\u003eFollow the manufacturer's testing and commissioning procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 12px;\"\u003e\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Electrical installation and termination must be carried out by suitably qualified personnel in accordance with manufacturer instructions and applicable regulations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- RELATED PRODUCTS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eComplete Your Snow Melting Installation\u003c\/h3\u003e\n\u003cp\u003eInsulation \u0026amp; More supplies trace heating products and supports enquiries for associated controls and installation accessories.\u003c\/p\u003e\n\u003cdiv class=\"related\"\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Trace Heating Controllers \u003c\/strong\u003e\n\u003cp\u003eExplore temperature controllers and enquire about compatible snow and moisture sensing equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/collections\/trace-heating-controllers-thermostats\"\u003e View Controllers \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Trace Heating Cables \u003c\/strong\u003e\n\u003cp\u003eBrowse additional self-regulating heating cables for frost protection and temperature maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/collections\/trace-heating-cables\"\u003e Browse Heating Cables \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Installation Accessories \u003c\/strong\u003e\n\u003cp\u003eContact our team regarding suitable connection kits, cable fixings and termination components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/pages\/contact\"\u003e Enquire About Accessories \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- MANUFACTURER DOCUMENTATION --\u003e\u003c!-- TRADE CTA --\u003e\n\u003csection class=\"cta\"\u003e\n\u003cdiv class=\"eyebrow\" style=\"color: #8dc5ff;\"\u003eINSULATION \u0026amp; MORE | COMMERCIAL SUPPLY\u003c\/div\u003e\n\u003ch3\u003ePlanning a Commercial Snow Melting or De-Icing Project?\u003c\/h3\u003e\n\u003cp\u003eWhether you need heating cable for a car park ramp, commercial entrance, access road or concrete pavement, our team can assist with product enquiries and project quotations.\u003c\/p\u003e\n\u003cp\u003eWe support M\u0026amp;E contractors, electrical installers and commercial buyers with trace heating cables, controls and installation accessories.\u003c\/p\u003e\n\u003cdiv class=\"actions\"\u003e\n\u003ca class=\"btn btn-red\" href=\"https:\/\/insulation-more.co.uk\/pages\/your-one-stop-shop-for-business-commercial-insulation\"\u003e Request Trade Pricing \u003c\/a\u003e \u003ca class=\"btn btn-outline\" href=\"https:\/\/insulation-more.co.uk\/pages\/contact\"\u003e Contact Our Team \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border-top: 1px solid rgba(255,255,255,.2); padding-top: 13px; margin-top: 19px; font-size: 12px; color: #d8e7f5;\"\u003e✓ Trade and Volume Enquiries   ✓ Product Selection Support   ✓ UK Delivery Options\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Solco","offers":[{"title":"Default Title","offer_id":40715446354002,"sku":"SMSR1002-CX-SELF-REGULATING-HEATING-CABLE","price":19.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1172\/9930\/files\/solco-pyroelec-smsr1002-cx-self-regulating-heating-cable-commercial-commercial-882.webp?v=1708681212","url":"https:\/\/insulation-more.co.uk\/products\/smsr1002-cx-self-regulating-heating-cable","provider":"Insulation \u0026 More","version":"1.0","type":"link"}