{"product_id":"pyex-ep-rtd-ex-temperature-sensing-kit-pipe-and-ambient-rtd-probe","title":"PYEX-EP-RTD Ex Temperature Sensing Kit – Pipe and Ambient RTD Probe","description":"\u003cstyle\u003e\n.im-pyexrtd{\n  --blue:#2D89F7;\n  --navy:#142D46;\n  --red:#EC2D2C;\n  --text:#34465A;\n  --muted:#617287;\n  --pale:#F3F7FC;\n  --border:#DDE7F1;\n  font:14px\/1.65 Arial,Helvetica,sans-serif;\n  color:var(--text);\n  max-width:100%;\n}\n.im-pyexrtd *{box-sizing:border-box}\n.im-pyexrtd h2,.im-pyexrtd h3{\n  color:var(--navy);\n  line-height:1.35;\n  font-weight:700;\n  margin:0 0 12px;\n}\n.im-pyexrtd h2{font-size:21px}\n.im-pyexrtd h3{font-size:18px}\n.im-pyexrtd p{margin:0 0 12px}\n.im-pyexrtd section{margin-bottom:24px}\n.im-pyexrtd .intro{\n  background:#F1F7FF;\n  border:1px solid #D8E8FC;\n  border-left:4px solid var(--blue);\n  border-radius:7px;\n  padding:19px;\n}\n.im-pyexrtd .eyebrow{\n  color:#1672DB;\n  font-size:11px;\n  font-weight:700;\n  letter-spacing:1px;\n  text-transform:uppercase;\n  margin-bottom:8px;\n}\n.im-pyexrtd .heading{\n  border-bottom:2px solid var(--blue);\n  padding-bottom:9px;\n  margin-bottom:14px;\n}\n.im-pyexrtd .stats{\n  display:grid;\n  grid-template-columns:repeat(4,minmax(0,1fr));\n  gap:9px;\n  margin-bottom:24px;\n}\n.im-pyexrtd .stat{\n  background:var(--pale);\n  border:1px solid var(--border);\n  border-radius:7px;\n  padding:13px 8px;\n  text-align:center;\n}\n.im-pyexrtd .stat strong{\n  display:block;\n  color:var(--blue);\n  font-size:19px;\n  line-height:1.35;\n}\n.im-pyexrtd .stat span{\n  display:block;\n  color:var(--muted);\n  font-size:11px;\n  margin-top:5px;\n}\n.im-pyexrtd .features{\n  display:grid;\n  grid-template-columns:repeat(2,minmax(0,1fr));\n  gap:11px;\n}\n.im-pyexrtd .feature{\n  background:#fff;\n  border:1px solid var(--border);\n  border-radius:7px;\n  padding:15px;\n}\n.im-pyexrtd .feature strong{\n  display:block;\n  color:var(--navy);\n  margin-bottom:5px;\n}\n.im-pyexrtd .feature p{\n  font-size:13px;\n  color:var(--muted);\n  margin:0;\n}\n.im-pyexrtd .applications{\n  display:grid;\n  grid-template-columns:repeat(2,minmax(0,1fr));\n  gap:11px;\n}\n.im-pyexrtd .application{\n  background:var(--pale);\n  border-top:3px solid var(--blue);\n  border-radius:6px;\n  padding:15px;\n}\n.im-pyexrtd .application strong{\n  display:block;\n  color:var(--navy);\n  margin-bottom:6px;\n}\n.im-pyexrtd .application p{\n  font-size:13px;\n  margin:0;\n}\n.im-pyexrtd .table-wrap{overflow-x:auto}\n.im-pyexrtd table{\n  width:100%;\n  border-collapse:collapse;\n  font-size:13px;\n}\n.im-pyexrtd th{\n  background:var(--navy);\n  color:#fff;\n  text-align:left;\n  padding:11px 13px;\n}\n.im-pyexrtd td{\n  padding:10px 13px;\n  border-bottom:1px solid var(--border);\n  vertical-align:top;\n}\n.im-pyexrtd tr:nth-child(even) td{\n  background:var(--pale);\n}\n.im-pyexrtd .spec td:first-child{\n  width:44%;\n  color:var(--navy);\n  font-weight:600;\n}\n.im-pyexrtd .info{\n  background:#F1F7FF;\n  border:1px solid #D8E8FC;\n  border-radius:7px;\n  padding:16px;\n}\n.im-pyexrtd .info p:last-child{margin:0}\n.im-pyexrtd ul{\n  padding-left:21px;\n  margin:9px 0;\n}\n.im-pyexrtd li{margin-bottom:6px}\n.im-pyexrtd .related{\n  display:grid;\n  grid-template-columns:repeat(3,minmax(0,1fr));\n  gap:11px;\n}\n.im-pyexrtd .related-item{\n  display:flex;\n  flex-direction:column;\n  justify-content:space-between;\n  background:var(--pale);\n  border:1px solid var(--border);\n  border-radius:7px;\n  padding:15px;\n}\n.im-pyexrtd .related-item strong{\n  display:block;\n  color:var(--navy);\n}\n.im-pyexrtd .related-item p{\n  margin:6px 0 13px;\n  color:var(--muted);\n  font-size:12px;\n}\n.im-pyexrtd .btn{\n  display:inline-block;\n  padding:10px 15px;\n  border-radius:5px;\n  font-size:13px;\n  font-weight:700;\n  line-height:1.4;\n  text-align:center;\n  text-decoration:none!important;\n}\n.im-pyexrtd .btn-blue{\n  background:var(--blue);\n  color:#fff!important;\n}\n.im-pyexrtd .btn-blue:hover{background:#176FD6}\n.im-pyexrtd .btn-red{\n  background:var(--red);\n  color:#fff!important;\n}\n.im-pyexrtd .btn-outline{\n  background:transparent;\n  border:1px solid #fff;\n  color:#fff!important;\n}\n.im-pyexrtd .related-item .btn{\n  width:100%;\n  display:block;\n  font-size:12px;\n  padding:9px;\n}\n.im-pyexrtd .cta{\n  background:linear-gradient(120deg,#142D46,#1B4875);\n  color:#fff;\n  border-radius:9px;\n  padding:23px;\n}\n.im-pyexrtd .cta h3{\n  color:#fff;\n  font-size:20px;\n}\n.im-pyexrtd .cta p{color:#E1EBF6}\n.im-pyexrtd .actions{\n  display:flex;\n  flex-wrap:wrap;\n  gap:10px;\n  margin-top:16px;\n}\n.im-pyexrtd .fine{\n  font-size:12px;\n  color:var(--muted);\n}\n@media(max-width:700px){\n  .im-pyexrtd .stats{\n    grid-template-columns:repeat(2,minmax(0,1fr));\n  }\n  .im-pyexrtd .related{grid-template-columns:1fr}\n}\n@media(max-width:480px){\n  .im-pyexrtd .features,\n  .im-pyexrtd .applications{\n    grid-template-columns:1fr;\n  }\n  .im-pyexrtd h2{font-size:19px}\n  .im-pyexrtd .intro,\n  .im-pyexrtd .cta{padding:16px}\n  .im-pyexrtd .actions{flex-direction:column}\n  .im-pyexrtd .actions .btn{width:100%}\n}\n\u003c\/style\u003e\n\u003cdiv class=\"im-pyexrtd\"\u003e\n\u003c!-- INTRODUCTION --\u003e\n\u003csection class=\"intro\"\u003e\n\u003ch2\u003eSOLCO PYEX-EP-RTD Ex Temperature Sensing Kit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSOLCO PYEX-EP-RTD\u003c\/strong\u003e is an \u003cstrong\u003eEx-certified temperature sensing kit\u003c\/strong\u003e incorporating an RTD sensor probe and protective enclosure for industrial electric trace heating systems.\u003c\/p\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003epipeline and ambient temperature sensing\u003c\/strong\u003e, the product is intended for hazardous-location applications including petrochemical plants, gas plants, shipbuilding and offshore installations.\u003c\/p\u003e\n\u003cp\u003eThe enclosure is made from \u003cstrong\u003efibreglass-reinforced polyester\u003c\/strong\u003e, with a UV-resistant and electrically conductive surface.\u003c\/p\u003e\n\u003cp style=\"margin: 0;\"\u003eThe published protection type is \u003cstrong\u003eEx e IIC Gb\u003c\/strong\u003e, with a \u003cstrong\u003eT6 to T2\u003c\/strong\u003e temperature classification range depending on the heating cable and RTD probe.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- QUICK SPECIFICATIONS --\u003e\n\u003cdiv class=\"stats\"\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003eIP64\u003c\/strong\u003e \u003cspan\u003eAssembled Protection\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e2.0m\u003c\/strong\u003e \u003cspan\u003eMaximum RTD Probe Length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e7J\u003c\/strong\u003e \u003cspan\u003eImpact Strength\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cstrong\u003e2.5mm²\u003c\/strong\u003e \u003cspan\u003eMaximum Terminal Conductor\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SENSING APPLICATIONS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003ePipeline and Ambient Temperature Sensing\u003c\/h3\u003e\n\u003cp\u003eSOLCO identifies two sensing applications for the PYEX-EP-RTD kit.\u003c\/p\u003e\n\u003cdiv class=\"applications\"\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003ePipeline Temperature Sensing\u003c\/strong\u003e\n\u003cp\u003eRTD sensing for pipelines within industrial electric trace heating systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"application\"\u003e\n\u003cstrong\u003eAmbient Temperature Sensing\u003c\/strong\u003e\n\u003cp\u003eRTD sensing of ambient temperature in industrial trace heating applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eKey Product Features\u003c\/h3\u003e\n\u003cdiv class=\"features\"\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003eEx Protection Type\u003c\/strong\u003e\n\u003cp\u003eManufacturer-published protection type: Ex e IIC Gb.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003eRTD Temperature Probe\u003c\/strong\u003e\n\u003cp\u003eMineral-insulated RTD sensing probe extendable up to 2.0m.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003eFibreglass-Reinforced Enclosure\u003c\/strong\u003e\n\u003cp\u003ePolyester enclosure with published dimensions of 122 x 120 x 90mm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003eUV-Resistant Surface\u003c\/strong\u003e\n\u003cp\u003eEnclosure surface specified as UV-resistant and electrically conductive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003eM16 Metallic Cable Gland\u003c\/strong\u003e\n\u003cp\u003eRTD probe enters through an M16 metallic gland with compression seal.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature\"\u003e\n\u003cstrong\u003e2.5mm² Terminal Block\u003c\/strong\u003e\n\u003cp\u003eSupplied with a terminal block supporting conductors up to 2.5mm².\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- INGRESS PROTECTION --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eEnclosure and Assembly Protection Ratings\u003c\/h3\u003e\n\u003cp\u003eSOLCO publishes separate ingress protection ratings for the junction box component and the assembled trace heating arrangement.\u003c\/p\u003e\n\u003cdiv class=\"table-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003ePublished Protection\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Box Component\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly with Trace Heating Cable\u003c\/td\u003e\n\u003ctd\u003eIP64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eSOLCO PYEX-EP-RTD Technical Specifications\u003c\/h3\u003e\n\u003cdiv class=\"table-wrap\"\u003e\n\u003ctable class=\"spec\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003ePYEX-EP-RTD\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSOLCO Pyroelec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Code\u003c\/td\u003e\n\u003ctd\u003ePYEX-EP-RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEx Temperature Sensing Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Applications\u003c\/td\u003e\n\u003ctd\u003ePipeline and Ambient Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eEx e IIC Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembled Ingress Protection\u003c\/td\u003e\n\u003ctd\u003eIP64 When Assembled with Trace Heating Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Box Rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Classification\u003c\/td\u003e\n\u003ctd\u003eT6 to T2, Depending on Heating Cable and Sensor Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpact Strength\u003c\/td\u003e\n\u003ctd\u003e7J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurface Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10⁹ Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlammability\u003c\/td\u003e\n\u003ctd\u003eSelf-Extinguishing UL94 V-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Conductor\u003c\/td\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Probe Construction\u003c\/td\u003e\n\u003ctd\u003eMineral Insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum RTD Probe Length\u003c\/td\u003e\n\u003ctd\u003e2.0m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Gland\u003c\/td\u003e\n\u003ctd\u003eM16 Metallic Gland with Compression Seal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eFibreglass-Reinforced Polyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Surface\u003c\/td\u003e\n\u003ctd\u003eUV-Resistant and Electrically Conductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Dimensions\u003c\/td\u003e\n\u003ctd\u003e122 x 120 x 90mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Brackets\u003c\/td\u003e\n\u003ctd\u003ePipe- and Wall-Mount Brackets Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- KIT COMPONENTS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eKit Components Identified by SOLCO\u003c\/h3\u003e\n\u003cdiv class=\"info\"\u003e\n\u003cp\u003eSOLCO identifies the following components within the PYEX-EP-RTD kit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP66-rated junction box.\u003c\/li\u003e\n\u003cli\u003e2.5mm² terminal block.\u003c\/li\u003e\n\u003cli\u003eEx-certified RTD sensing probe.\u003c\/li\u003e\n\u003cli\u003eM16 metallic cable gland with compression seal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMounting brackets:\u003c\/strong\u003e Pipe- and wall-mount brackets are sold separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- TEMPERATURE CLASSIFICATION --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eEx Temperature Classification\u003c\/h3\u003e\n\u003cdiv class=\"info\"\u003e\n\u003cp\u003eSOLCO specifies a \u003cstrong\u003eT6 to T2\u003c\/strong\u003e temperature classification range for PYEX-EP-RTD.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer states that the applicable temperature rating depends on the type of heating cable and sensor probe.\u003c\/p\u003e\n\u003cp\u003eRefer to the manufacturer installation manual for the relevant temperature rating requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- MANUFACTURER RESOURCE --\u003e\u003c!-- RELATED PRODUCTS --\u003e\n\u003csection\u003e\n\u003ch3 class=\"heading\"\u003eExplore Related Trace Heating Products\u003c\/h3\u003e\n\u003cp\u003eBrowse related trace heating controls, cables and installation accessories from Insulation \u0026amp; More.\u003c\/p\u003e\n\u003cdiv class=\"related\"\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Trace Heating Controllers \u003c\/strong\u003e\n\u003cp\u003eExplore controllers and thermostats in the I\u0026amp;M range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/collections\/trace-heating-controllers-thermostats\"\u003e View Controllers \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Industrial Trace Heating Cables \u003c\/strong\u003e\n\u003cp\u003eBrowse available trace heating cable products.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/collections\/trace-heating-cables\"\u003e View Heating Cables \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"related-item\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003e Trace Heating Accessories \u003c\/strong\u003e\n\u003cp\u003eExplore related installation and connection products.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ca class=\"btn btn-blue\" href=\"https:\/\/insulation-more.co.uk\/collections\/trace-heating-fixings-accessories\"\u003e View Accessories \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp class=\"fine\" style=\"margin-top: 10px;\"\u003eRelated categories are shown for product discovery. Specific equipment compatibility is not implied.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- TRADE CTA --\u003e\n\u003csection class=\"cta\"\u003e\n\u003cdiv class=\"eyebrow\" style=\"color: #8dc5ff;\"\u003eINSULATION \u0026amp; MORE | INDUSTRIAL SUPPLY\u003c\/div\u003e\n\u003ch3\u003eNeed Industrial Temperature Sensing Equipment?\u003c\/h3\u003e\n\u003cp\u003eContact Insulation \u0026amp; More for PYEX-EP-RTD pricing, quantity requirements and product enquiries.\u003c\/p\u003e\n\u003cp\u003eInclude the product code \u003cstrong\u003ePYEX-EP-RTD\u003c\/strong\u003e when requesting a quotation.\u003c\/p\u003e\n\u003cdiv class=\"actions\"\u003e\n\u003ca class=\"btn btn-red\" href=\"https:\/\/insulation-more.co.uk\/pages\/your-one-stop-shop-for-business-commercial-insulation\"\u003e Request Trade Pricing \u003c\/a\u003e \u003ca class=\"btn btn-outline\" href=\"https:\/\/insulation-more.co.uk\/pages\/contact\"\u003e Contact Our Team \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"Solco","offers":[{"title":"Default Title","offer_id":59341161759094,"sku":"PYEX-EP-RTD","price":422.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1172\/9930\/files\/PYEX-EP-RTD.png?v=1794567703","url":"https:\/\/insulation-more.co.uk\/products\/pyex-ep-rtd-ex-temperature-sensing-kit-pipe-and-ambient-rtd-probe","provider":"Insulation \u0026 More","version":"1.0","type":"link"}